background image

Communication  
Systems Inc.

PDI-P23LCDD Quick Start Guide 

Page 3 of 8 

Better Solutions Are Within Reach™ 

INSTALLATION INSTRUCTIONS

PDi Communication Systems, Inc.   40 Greenwood Lane   Springboro, Ohio 45066 USA   PH +1-937-743-6010  PH +1-937-743-5664  

Document Number:  PD196I148R1.DOC 

LOCATION GUIDELINES 

The model PDI-P23LCDD Hospital Grade LCD TV is a specialized LCD television.  This TV is intended for entertainment 
and educational purposes for use in a hospital, a nursing home, a medical-care center, or a similar health-care facility in 
which installation is limited to a non-hazardous area in accordance with the National Electrical Code, ANSI/NFPA 70.  The 
PDI-P23LCDD is designed for mounting to PDI manufactured mounts.  Installation of the TV on any other mount is not 
recommended. 

WARNING

:  The TV’s VESA mounting 

holes are designed for M4 metric screws 
only.  Use of a non-PDI approved mount or 
SAE hardware could result in a condition 
where the TV could unexpectedly fall and 
cause injury or death. 

The PDI-P23LCDD TV mounts at the foot of a patient’s bed with the supplied bracket.  Select a location that is near an AC 
wall outlet and that does not expose the TV to bright room lights or sunlight if possible.  The LCD TV also requires 
connection of both CATV cable signal and across-room wiring for the pillow speaker. 

OSHPD (State of California Only)

The combined weight of the PDI-P23LCDD TV and PDI wall mount totals less than 20 pounds.  At the time of this writing, 
the involvement of a written, submitted, reviewed, and approved plan by OSHPD is not required to install the  
PDI-P23LCDD TV in the state of California.   

CABLE SYSTEM GROUNDING 

The coax cable system connected to the PDI-P23LCDD TV should be grounded in accordance with the National Electrical 
Code, ANSI/NFPA 70. The code provides guidelines for proper grounding and, in particular, specifies that the cable 
ground shall be connected to the grounding system of the building, as close to the point of the cable entry as practical. 

The apparatus with Class I construction shall be connected to a mains socket outlet with a protective 
earthing connection. 

WALL MOUNTING WITH PD168-003 STANDARD WALL BRACKET 

(Not supplied with TV)

1. 

Refer to Figure 1.  Select a location on the wall 
approximately 8 inches below the ceiling.   

NOTE: Do not locate AC, Across-Room Wiring, and 
CATV Signal outlets below the Wall Bracket’s 
location as it will cause clearance issues and 
interfere with the TV’s cabinet when mounted to the 
bracket.   

Position the Wall Bracket and locate two mounting 
holes.  Secure the bracket to the wall (mounting 
hardware is not included).   

2. 

Refer to Figure 2.  Position the Back Mount on the 
LCD TV cabinet.  Attach with four M4 screws 
provided. 

3. 

Mate the Back Mount to the Wall Bracket making 
sure the pivot pins are retained in the “U” shaped 
slot.  Using the pilfer security driver packed with the 
hardware, secure with two 10x32 pilfer screws. 

4. 

Connect the AC line cord, Pillow Speaker Jumper 
Cable, and CATV Coax Cable.

5. 

The TV’s tilt can be adjusted by loosening both Pilfer 
Screws, adjusting tilt, and then tighten.

Содержание PDI-P23LCDD

Страница 1: ...ectrical Code The code provides guidelines for proper grounding and in particular specifies that the cable ground shall be connected to the grounding system of the building as close to the point of th...

Страница 2: ...e apparatus has been damaged in any way such as power supply cord or plug is damaged liquid has been spilled or objects have fallen into the apparatus the apparatus has been exposed to rain or moistur...

Страница 3: ...At the time of this writing the involvement of a written submitted reviewed and approved plan by OSHPD is not required to install the PDI P23LCDD TV in the state of California CABLE SYSTEM GROUNDING...

Страница 4: ...er A rear panel mounted switch allows use of different brands of pillow speakers and supports the major brands Zenith Philips and RCA pillow speakers WARNING DO NOT connect the pillow speaker circuit...

Страница 5: ...DOC NOTE A Jumper Cable is NOT supplied with the TV and must be ordered separately SPEAKER DATA SWITCH COMMON SPEAKER DATA SWITCH COMMON to 6 Pin Jumper Cable PD106 416 to Jumper Cable PD106 417 ACRO...

Страница 6: ...ble IRC or Cable HRC NOTE Most hospitals use the Cable STD signal style Auto Program The TV automatically scans each available channel for activity Channels that display activity are memorized into th...

Страница 7: ...rn to the preceding menu Minimum Volume For pillow speakers with an adjustment thumbwheel volume control always set a minimum volume level for the TV Set this level to any value other than 0 guarantee...

Страница 8: ...user interface for allowing any user to configure wireless audio functionality Wireless Audio Auto Pairing 1 In the Wireless Audio menu press CH CH button to select the Wireless Audio Auto Pairing men...

Отзывы: