background image

 

 

 

 

Hardware Reference Manual 
 

Document Number: 100130-00 
Revision F

 

 

April 2020 
 
 
 
 
 

 

SeeG

ull

®

 HB

fle

x

 

TM 

 

 

Содержание SeeGull HBflex

Страница 1: ...Hardware Reference Manual Document Number 100130 00 Revision F April 2020 SeeGull HB flex TM...

Страница 2: ...A EV DO Holdover Operation 22 5 RF Antenna Information 23 5 1 Antenna Verification 23 5 2 Cellular Antennas 23 5 3 GPS Antenna Information 25 5 4 Wi Fi Wireless Adapter 26 6 Walk Test Kit Information...

Страница 3: ...ork and Sharing Center 20 Figure 9 Change Adapter Settings 20 Figure 10 Local Area Connection Properties 20 Figure 11 Internet Protocol Version 20 Figure 12 Obtain IP Address Automatically 20 Figure 1...

Страница 4: ...TE LAA NB IoT WCDMA GSM CDMA EV DO P25 TETRA DMR and Wi Fi technologies which can all be measured simultaneously The following 3GPP bands are supported for 5G New Radio NR N1 UL 1920 MHz 1980 MHz DL 2...

Страница 5: ...MHz UMTS E UTRA 9 1700 MHz Japan E UTRA 10 Ext 2100 MHz AWS E UTRA 11 1500 MHz Japan E UTRA 12 Lower 700 MHz A B C E UTRA 12 17 Lower 700 MHz A B C and Lower 700 MHz B C E UTRA 13 Upper 700 MHz C E U...

Страница 6: ...MHz MS Wi Fi Bands 2400 2484 MHz 4900 6000 MHz TETRA Public Safety 380 390 Band 380 390 MHz MS 390 400 MHz BS TETRA Public Safety 410 420 Band 410 420 MHz MS 420 430 MHz BS TETRA Public Safety 450 460...

Страница 7: ...R1 and 8 FR2 NRTop N Reference Signal Scan PCI Beam Index PSS_RP PSS_RQ PSS_CINR SSS_RP SSS_RQ SSS_CINR SSS_delay spread RSPBCH_RP RSPBCH_RQ RSPBCH_CINR SSB_RSSI SSB_RP SSB_RQ SSB_CINR SSB_Idx MIB Tim...

Страница 8: ...c Io Pilot Delay and Delay EV DO Maximum of Channels 24 Top N Scan Ec Ec Io and Aggregate Ec Io Pilot Delay and Delay W Fi Channelized RSSI measurements for 2 4GHz 4 9GHz and 5GHz Top N measurement in...

Страница 9: ...bles the user to communicate wirelessly to an Android device Bluetooth requires an antenna to operate and comes with the scanner For more information please visit www pctel com 1 3 Notices WARNING The...

Страница 10: ...an be installed at the time of purchase or later on as a field upgradeable option Please contact your PCTEL sales or marketing representative for pricing and delivery information Technologies The foll...

Страница 11: ...lable for TD LTE and provides power of the resource block and slot of the TD LTE frame This enables users to identify interference that is time slots or frequency RBs selective to obtain a snapshot of...

Страница 12: ...hannel List Message The SeeGull HBflex supports scanning of numerous GSM and LTE BCCH and WCDMA BCH channels during the same test Mobile Blindscan Option Mobile Measurement OP505 All Technologies GSM...

Страница 13: ...an SMA male connector at the end of the cable Power Source Requirements Maximum power the SeeGull HBflex scanning receiver draws 25 watts max Voltage range for the HBflex scanning receiver 9 to 17 VDC...

Страница 14: ...e Manual PCTEL Inc Page 14 Rev F 3 Installation This section describes how to set up the SeeGull HBflex scanning receiver Figure 2 SeeGull HBflex Scanning Receiver Top View Figure 3 SeeGull HBflex Sca...

Страница 15: ...mmWave measurements and not sub 6GHz measurements See Figure 4 2 24 40GHz only When carrying out mmWave measurements only 24GHz to 40GHz ensure that the DC1 and DC2 ports have RF cable connectors OP3...

Страница 16: ...eiver Front Display DC1 and DC2 connecting RF connector cable to down convert mmWave to sub 6GHz DC1 RF1 and DC2 RF2 RF Connector Cable OP306 SMB Connector for the GPS Antenna USB data connector for P...

Страница 17: ...or HBflex 5G NR measurements with single antenna simultaneous mode and dual antenna mode Measurement type Feature Support 64 Beams 40 ms SSB periodicity Dynamic spectrum sharing Multi channel blind sc...

Страница 18: ...ns solid blue again The Com port LED blinks green during data transfer 4 Operation This section discusses calibration software upgrades and integrating the SeeGull HBflex scanning receiver into the us...

Страница 19: ...onnection is lost without a proper shutdown the scanner must be power cycled before accepting a new connection Ethernet Using DHCP Using this method an IP address Subnet mask and Gateway are acquired...

Страница 20: ...Figure 9 Change Adapter Settings 5 Right click Local Area Connection icon then click Properties Figure 10 Local Area Connection Properties 6 Double click Internet Protocol Version 4 TCP IPv4 Figure 11...

Страница 21: ...he connected PC The subnet mask number must be identical for both the scanner and connected PC Example PC IP Address XXX YYY ZZZ 2 Subnet Mask 255 255 255 0 Scanner IP Address XXX YYY ZZZ 100 Subnet M...

Страница 22: ...l to the connected PC The subnet mask number must be identical for both the scanner and connected PC Example PC IP Address 192 168 2 2 Subnet Mask 255 255 255 0 Scanner IP Address 192 168 2 100 Subnet...

Страница 23: ...oss cable extended temperature ranges and a frequency range wide enough to cover PCTEL s SeeGull HBflex scanning receiver Figure 14 OP278H The OP278H supports a wide frequency range from 698 MHz to 3...

Страница 24: ...d its base is designed to interface with standard NMO mobile mounts to facilitate existing installation upgrades on public safety vehicles Figure 17 OP697 wide spectrum multi band antenna For wide ran...

Страница 25: ...els depending on the frequency required OP691 Indoor Antenna 600 MHz 6 GHz OP452 Indoor Antenna Public Safety VHF UHF 700 MHz 800 MHz 5 3 GPS Antenna Information PCTEL offers a single standalone GPS a...

Страница 26: ...i Device 802 11 Version Security Mode PCTEL OP Proxim ORiNOCO USB 9100 US WD a b g n ac WEP WPA Personal WPA2 Personal and Open Network OP614 US OP614 WD Ubiquiti Networks SR71 USB a b g n WEP and Ope...

Страница 27: ...alk Testing that enables wireless engineers to address the three key steps of in building coverage assessment and planning Evaluating In building Coverage from Outside Networks Planning New In Buildin...

Страница 28: ...or an illustration of the power plug Loosen the fuse holding finger nut by turning it counter clockwise until the plug comes apart The fuse is inside the power plug housing and can be removed Figure 2...

Страница 29: ...stallation of any item s of equipment is not included in this warranty This warranty shall only apply to the Product purchased or licensed and shall not apply to any other equipment and its removal an...

Страница 30: ...ses the calibration and test process successfully receives a Certificate of Calibration This Certificate is shipped back with the unit The complexity of the calibration process precludes field calibra...

Страница 31: ...Level RP 132 dBm SCS 15 KHz Relative Accuracy CINR PSS SSS CINR 2 dB FD LTE and TD LTE Measurement Modes Top N Synchronization Channel Reference Signal P SCH S SCH and Resource Block Wideband Subband...

Страница 32: ...rowband Reference Signal NPSS Narrowband Primary Synchronization Signal NSSS Narrowband Secondary Synchronization Signal and Layer 3 Reporting Data Modes NRS RP RQ RSSI CINR Timeoffset NPSS RP RQ RSSI...

Страница 33: ...s ORiNOCO USB 9100 adapter is country specific Radio Configuration 802 11a b g n 802 11a b g n ac Data Modes Signal Strength Noise Level SNR Channel Number Channel Bandwidth BSSID Device Name SSID Sec...

Страница 34: ...over 8 to 20 dB 3 dB over 4 to 8 dB 1 dB over 118 to 10 dBm Adjacent channel rejection 20 dB Power Measurements Measurement Modes RSSI RSSI RSSI LTE 5G NR 11 050 ch sec WCDMA GSM NB IoT 4 250 ch sec...

Страница 35: ...c Typical GPS Measurement Modes 56 Channel Internal Receiver Vertical Position Accuracy 2 5 meters Horizontal Accuracy Altitude 2x Vertical Position Accuracy Acquisition Time Cold Start 30 sec Hot Sta...

Страница 36: ...the new measurement The NB IoT carrier follows the 3GPP FD LTE channel raster It has a channel index value of 100 kHz To align the NB IoT signal with standard LTE the 3GPP standard introduces a freque...

Страница 37: ...kHz offset for the channel raster The scanner provides RP RQ CINR Time offset values for primary and secondary synchronization channels as well as reference signal In order to monitor the standard LTE...

Страница 38: ...A N A N A 3MHz N A N A N A N A 5MHz 24 7 5 24 7 5 10MHz 46 47 48 49 2 5 2 5 7 5 2 5 46 47 48 49 2 5 2 5 7 5 2 5 15MHz 69 70 71 72 73 74 7 5 2 5 2 5 7 5 2 5 2 5 69 70 71 72 73 74 7 5 2 5 2 5 7 5 2 5 2...

Страница 39: ...ange without notice PCTEL assumes no responsibility or makes no warranties for any errors that may appear in this document and disclaims any implied warranty of merchantability or fitness for a partic...

Отзывы: