background image

 

SeeGull

®

 EX

flex

®

 Reference Manual 

 

 

PCTEL, Inc., RF Solutions 

Page 5 

Revision F 

For more information about the SeeGull 
EX

flex

, please contact your sales or 

marketing representative (contact 
information provided in 

Section 8

). 

Features 

  Fast scanning speeds 

  High dynamic range 

  Low false detection rate 

  Built-in GPS 

  LTE FDD Measurement Averaging 

  Blind Scan for all technologies  

  LTE (FDD), TD-LTE, UMTS 

(WCDMA/HSPA(+), GSM Layer 3 

  USB Interface 

  Plug-and-play capabilities 

  Compatibility with industry-leading 

drive test, data analysis, and RF 
planning tools 

  Modular architecture for easy 

upgrades 

  Sleek, durable design 

 

Supported Measurements 

LTE (FDD and TDD) 

  Maximum # of Channels: 24 

  eTop N Reference Signal Scan 

  P-SCH/S-SCH  

  RSRP, RSRQ  

  CINR 

  Cyclic Prefix  

  Time Offset  

  Multi-Path Delay Spread  

TD-LTE Specific 

  Uplink/Downlink Configuration # 

  DwPTS Symbol 

GSM 

  BSIC Decoding Scan 

  RSSI Channel Scan 

  C/I (Co-Channel Interference) 

UMTS [WCDMA/HSPA(+)] 

  Maximum # of Channels: 24 

  Top N Scan 

  P-SCH/S-SCH Scan 

  Io 

  Ec/Io and Aggregate Ec/Io 

  Signal to Interference Ratio (SIR) 

  Rake Finger Count 

  Time Offset 

  Delay Spread 

CDMA 

  Maximum # of Channels: 24 

  Top N Scan 

  Ec 

  Ec/Io and Aggregate Ec/Io 

  Pilot Delay and Delay 

EV-DO 

  Maximum # of Channels: 24 

  Top N Scan 

  Ec 

  Ec/Io and Aggregate Ec/Io 

  Pilot Delay and Delay 

TD-SCDMA 

  Maximum # of Channels: 34 

  Top N Beacon Scan  

  Ec 

  Io 

  P-CCPCH Midamble Ec/Io 

  Sync DL Ec/Io 

  Signal to Interference Ratio (SIR) 

  Time Offset 

 

 

MULTI-TECHNOLOGY 

  Aggregate Power measurement 

(RSSI, EPS or Spectrum Analysis) 

  Delay and Signal Strength of 

neighboring cells 

  RSSI Channel Scans  

  Spectrum Analyzer measurements 

  High Performance GPS Receiver 

 

Blind Scan 

Blind Scan is available for LTE FDD, 
TD-LTE, UMTS [WCDMA/HSPA], GSM, 
CDMA, EV-DO and TD-SCDMA 

Содержание SeeGull EXflex

Страница 1: ...Hardware Reference Manual Document Number 100092 00 Revision F March 2016 SeeGull EX flex...

Страница 2: ...Holdover Option Operation 13 5 RF Antenna Information 14 5 1 Antenna Verification 14 5 2 Cellular Antennas 14 5 3 GPS Antenna Information 15 6 Walk Test Kit Information 16 6 1 Walk Test Kits 16 6 2 I...

Страница 3: ...6 SeeGull EXflex Scanning Receiver front display 12 Figure 7 OP123 14 Figure 8 OP278H 14 Figure 9 OP27H8 and OP379H Gain 14 Figure 10 OP379H 15 Figure 11 OP034H 15 Figure 12 OP207 Walk Test Kit 16 Fig...

Страница 4: ...SM and TD SCDMA technologies which can all be measured simultaneously The following bands are supported for LTE FDD with a subset of these bands supported for UMTS WCDMA HSPA CDMA EV DO and GSM R GSM...

Страница 5: ...i Path Delay Spread TD LTE Specific Uplink Downlink Configuration DwPTS Symbol GSM BSIC Decoding Scan RSSI Channel Scan C I Co Channel Interference UMTS WCDMA HSPA Maximum of Channels 24 Top N Scan P...

Страница 6: ...Please turn off the scanning receiver during a thunderstorm and if applicable take the antenna inside the car before a thunderstorm approaches The scanning receiver itself is not intended for in weath...

Страница 7: ...ion link allows the host to control the operation of the scanner and to receive measurement results Refer to Section 4 for more details Figure 1 SeeGull EXflex Scanning Receiver 2 2 Initial Inspection...

Страница 8: ...f information about the signal spectrum that is not obtainable from the standard channel power measurement The Spectrum Analyzer measures and reports power spectral density using frequency domain tech...

Страница 9: ...dcast call control GPRS mobility management transparent transport and session management Radio resource management SMS messages Location services Uplink Interference parameters UMTS WCDMA HSPA only Th...

Страница 10: ...EXflex Scanning Receiver draws 21 watts max 17 watts typical Voltage range for the EXflex Scanning Receiver 8 to 16 VDC Use a car battery a 12 volt battery or an AC DC adapter It is imperative that th...

Страница 11: ...and Figure 4 Care should be taken when mounting this unit in a system enclosure rack or case not to obstruct airways Unobstructed convection airflow is recommended Figure 3 SeeGull EXflex Scanning Rec...

Страница 12: ...Connect the power cable to the SeeGull EXflex Scanning Receiver and to the car cigarette lighter adapter After the power is applied the LED on the receiver blinks orange After a short delay the light...

Страница 13: ...eeded to incorporate new features or bug fixes Please note that some upgrades can only be performed at PCTEL s factory 4 3 Controlling the Scanner and Acquiring Data A unit is controlled and the measu...

Страница 14: ...x Scanning Receiver Figure 7 OP123 The OP123 supports a frequency range of 450 to 512 MHz It provides unity gain1 of 1 dBi across the entire spectrum The antenna comes standard with a magnetic 1 dBi g...

Страница 15: ...on pull off adapter for the GPS Figure 10 OP379H 5 3 GPS Antenna Information PCTEL offers a single standalone GPS antenna the OP034H The OP034H is a High Gain GPS standalone antenna which comes stand...

Страница 16: ...e PCTEL s Walk Test Kit provides the right solution for Walk Testing that enables wireless engineers to address the three key steps of in building coverage assessment and planning Evaluating In buildi...

Страница 17: ...er plug end from the power source See Figure 13 for an illustration of the power plug Loosen the fuse holding finger nut by turning it counter clockwise until the plug comes apart The fuse is inside t...

Страница 18: ...ty period The expense of removal and reinstallation of any item s of equipment is not included in this warranty This warranty shall only apply to the Product purchased or licensed and shall not apply...

Страница 19: ...pped back with the unit The complexity of the calibration process precludes field calibration It is highly recommended that PCTEL s scanning receivers be returned to the factory annually to maintain t...

Страница 20: ...MHZ 1475 2700 MHZ Table 4 SeeGull EXflex Antennas Walk Test Kits Battery Packs Part Number Description OP024 UNIV INPUT AC 12VDC ADPT OP207 WALK TEST INDOOR KIT CX EX EXFLEX INCLUDES BAG BATTERY KIT A...

Страница 21: ...ion Service Fixed Cost Repair Service Part Number Description OPR05 RMA EVALUATION FEE QUOTED TO CUSTOMERS WITH UNITS OUTSIDE OF WARRANTY WHO SEND UNITS IN FOR EVALUATION ONLY CHARGED IF UNIT DOES NOT...

Страница 22: ...f merchantability or fitness for a particular purpose Further PCTEL shall not be liable for incidental consequential or other damages in connection with the use of this document Copyright Information...

Страница 23: ......

Отзывы: