CLEANING FIBER OPTIC CONNECTORS
1. Use a lint-free cloth (3cm x 3cm recommended) .
2. Moisten one-half of the cloth with >90% ethyl alcohol.
3. Gently swab the connector ’s endface.
4. Using the dry half of the cloth, wipe the endface.
5. Allow the connector to air -dry completely before inserting
into the adapter port.
CAUTION:
Do NOT spray compressed air directly into the
connector’s endface. Air blasting may cause abrasion damage.
!
DANGER
-
AVOID DIRECT OCULAR EXPOSURE TO THE LASER BEAM AT ALL
TIMES.
Invisible radiation continues when operating with an open or disconnected
fiber optic cable. Such exposure may result in severe physical damage. Do NOT
operate this unit with a broken, disconnected, or unterminated fiber connector.
INSTALLATION
Transmitter Installation
Page 7
Step 1
Align the transmitter’s base plate with the rack -mount cabinet guides. Slide unit
into position. Tighten the four (4) front panel mounting screws.
Step 2
Check to ensure for adequate ventilation of heat from all sides of the unit.
Maximum temperature at bottom of transmitter should not exceed 50
0
C.
In general, allow for a 1.75” vertical space above the installed unit to assist
heat dissipation.
Note: Transmitter will generate approximately 15
0
C heat over ambient.
Step 3
Install Power Supply.
Step 4
Ensure the Laser Key Switch on the front panel is in the OFF position.
Step 5
Check to confirm the Optical Connector is the correct, matched type.
Recommendation: Clean the optical connector endface before connecting to
the transmitter optical port.
Step 6
Connect the Fiber Optic interface.
OPTICAL Connection Procedure
1.
Check fiber optic cable for bends and creases that can distort transmitter
performance.
2.
Confirm the compatibility of fiber optic connectors. (FC/APC and SC/APC)
All manuals and user guides at all-guides.com