PCT PCT-FTX3R Скачать руководство пользователя страница 6

FUNCTION ANALYSIS

RF TEST

OPTICAL OUT

RF INPUT

POWER INPUT

RS-232 & RS-485

Display Board

Digital Board

Transmitter Module

Power Supply Module

Block Diagram

Page 6

1. 

DISPLAY BOARD  

Displays unit’s systems information and status.  

 

 

 

2. 

DIGITAL BOARD  

Connects power and data  of sub-component modules. 
Provides RS-232 and RS-485 connection ports. 

 

 

 

3. 

TRANSMITTER 

MODULE 

Delivers internal data to the DISPLAY BOARD and DIGITAL 
BOARD through I

2

C. 

Per option, includes AGC / MGC (Hybrid Module).  

 

 

 

4. 

POWER SUPPLY  

MODULE 

Provides input power: 90VAC to 260VAC @ 50/60Hz  

 

All manuals and user guides at all-guides.com

all-guides.com

Содержание PCT-FTX3R

Страница 1: ...5233 Toll Free 800 315 2253 Phone 480 813 0925 Fax 480 892 5537 www pctusa net Model Product Operations Manual PCT FTX3R VER 2 06282005 CATV 1310nm DFB Fiber Optic Transmitter All manuals and user gui...

Страница 2: ...tion with the purchaser s order for this product This manual contains information illustrations and technical data that pertain to the operation of model PCT FTX3R CATV 1310nm DFB fiber optic transmit...

Страница 3: ...ervices for remedial action Receiving Procedure Page 3 Index SUBJECT PAGE PACKING LIST RECEIVING PROCEDURE PRODUCT DESCRIPTION Overview Features Graphics SPECIFICATIONS Data Tables FUNCTION ANALYSIS B...

Страница 4: ...with a miniaturized circuit format that improves stability and service life T 19 Standard 1U Rack Design T High Performance Cooled DFB Laser Diode T 45 870 MHz Bandwidth T Automatic Manual Controls AG...

Страница 5: ...annels Item Spec Unit 4 1 RF input range 20 5 dBmV ch 4 2 CNR 51 0 dB 4 3 CSO 63 0 dB 4 4 CTB 67 0 dB 4 5 XMOD 65 0 dB 0 Test Condition Room temperature 25 C Optical Link fiber 10km attenuator Receive...

Страница 6: ...ormation and status 2 DIGITAL BOARD Connects power and data of sub component modules Provides RS 232 and RS 485 connection ports 3 TRANSMITTER MODULE Delivers internal data to the DISPLAY BOARD and DI...

Страница 7: ...e plate with the rack mount cabinet guides Slide unit into position Tighten the four 4 front panel mounting screws Step 2 Check to ensure for adequate ventilation of heat from all sides of the unit Ma...

Страница 8: ...ctioning properly the ALARM Display light will remain unlit A red light illumination of the ALARM Display indicates the transmitter is malfunctioning RF Connection Confirm the RF input power is set to...

Страница 9: ...put mV Monitors Optical Power Status Bias mA Monitors Laser Current Status Temp C Monitors Laser Temperature Status RF Menu RF Status AGC Level AGC MGC and Level Display AGC Set AGC MGC Select and Lev...

Страница 10: ...3R Set the analyzer to the appropriate function 2 Press UP or DOWN button to display RF Menu Press SELECT to display AGC MGC SET function LCD will indicate AGC Set 00 3 Press UP or DOWN button to sele...

Страница 11: ...c See Table 2 C type command response D Set Parameter Hex 1b See Table 3 D type command response RS232 RS485 Pin 1 NC Pin 1 NC Pin 2 TX Pin 2 TR Pin 3 RX Pin 3 RX Pin 4 NC Pin 4 TR Pin 5 GND Pin 5 RX...

Страница 12: ...or Binary 0 255 Major revision number equivalent to the first digit in display format 13 Firmware version minor Binary 0 255 Minor revision number equivalent to the last two digits in display format 1...

Страница 13: ...erature alarm status B0 temp low alarm B1 temp high alarm B2 temp too high alarm Laser will be shutdown when too high 3 Bias alarm status B0 Laser bias alarm 4 RF Mod Lvl Alarm status B0 RF level low...

Страница 14: ...ptical power still is lower the unit will require a factory check Contact PCT International Inc Cooling fan does not work The unit will require a factory check Contact PCT International Inc Troublesho...

Страница 15: ...S For Technical Assistance or Sales Information contact 1715 W Sunrise Blvd Gilbert AZ 85233 Phone 800 315 2253 480 813 0925 Fax 480 892 5537 www pctusa net info pctusa net All manuals and user guides...

Отзывы: