PCT PCT-FTX3R Скачать руководство пользователя страница 5

1. 

Optical Performance 

 

Item 

Spec. 

Unit 

1.1 

Optical Wavelength 

1310

±

20 

nm 

1.2 

Optical Output Power 

4 ~ 20 

mW 

 

2. 

RF Performance ( 45 ~ 870MHz ) 

 

Item 

Spec. 

Unit 

2.1 

RF Input Return Loss 

³

16 

dB 

2.2 

RF Flatness 

£

1.5

 

dB 

2.3 

AGC

±

5dB RF Variation 

 

dB 

 

3. 

Monitor Port Performance 

 

Item 

Spec. 

Unit 

3.1 

LCD 

2 x16 

characters 

3.2 

RF Monitor Point Value 

-20 

dB 

3.3 

RF Monitor Point Accuracy 

±

dB 

 

4. 

RF Link Performance ( NTSC – 79 Channels ) 

 

Item 

Spec. 

Unit 

4.1 

RF input range 

20

±

dBmV/ch 

4.2 

CNR 

³

51.0 

dB 

4.3 

CSO 

³

63.0 

dB 

4.4 

CTB 

³

67.0 

dB 

4.5 

XMOD 

³

65.0 

dB 

0

Test Condition: Room temperature: 25 C. Optical Link: fiber 10km + attenuator.
Receiver Input Power: -1 dBm.

5.

 

Electrical/Environmental/Physical

 

 

Item

 

5.1 

5.2 

5.3 

5.4 

5.5 

5.6 

5.7 

Power: 90 VAC to 260 VAC @ 50/60Hz

Control Interface: RS-232 and RS-485

0

0

Operating Temperature: 0 C to 50 C

Weight: 4.8kg

Dimensions: 483 W x 44 H x 392 D (mm)

Humidity: Max 85% non-condensing

0

0

Storage Temperature: -20 C to 70 C

SPECIFICATIONS

Data Tables

Page 5

£

1.0

All manuals and user guides at all-guides.com

Содержание PCT-FTX3R

Страница 1: ...5233 Toll Free 800 315 2253 Phone 480 813 0925 Fax 480 892 5537 www pctusa net Model Product Operations Manual PCT FTX3R VER 2 06282005 CATV 1310nm DFB Fiber Optic Transmitter All manuals and user gui...

Страница 2: ...tion with the purchaser s order for this product This manual contains information illustrations and technical data that pertain to the operation of model PCT FTX3R CATV 1310nm DFB fiber optic transmit...

Страница 3: ...ervices for remedial action Receiving Procedure Page 3 Index SUBJECT PAGE PACKING LIST RECEIVING PROCEDURE PRODUCT DESCRIPTION Overview Features Graphics SPECIFICATIONS Data Tables FUNCTION ANALYSIS B...

Страница 4: ...with a miniaturized circuit format that improves stability and service life T 19 Standard 1U Rack Design T High Performance Cooled DFB Laser Diode T 45 870 MHz Bandwidth T Automatic Manual Controls AG...

Страница 5: ...annels Item Spec Unit 4 1 RF input range 20 5 dBmV ch 4 2 CNR 51 0 dB 4 3 CSO 63 0 dB 4 4 CTB 67 0 dB 4 5 XMOD 65 0 dB 0 Test Condition Room temperature 25 C Optical Link fiber 10km attenuator Receive...

Страница 6: ...ormation and status 2 DIGITAL BOARD Connects power and data of sub component modules Provides RS 232 and RS 485 connection ports 3 TRANSMITTER MODULE Delivers internal data to the DISPLAY BOARD and DI...

Страница 7: ...e plate with the rack mount cabinet guides Slide unit into position Tighten the four 4 front panel mounting screws Step 2 Check to ensure for adequate ventilation of heat from all sides of the unit Ma...

Страница 8: ...ctioning properly the ALARM Display light will remain unlit A red light illumination of the ALARM Display indicates the transmitter is malfunctioning RF Connection Confirm the RF input power is set to...

Страница 9: ...put mV Monitors Optical Power Status Bias mA Monitors Laser Current Status Temp C Monitors Laser Temperature Status RF Menu RF Status AGC Level AGC MGC and Level Display AGC Set AGC MGC Select and Lev...

Страница 10: ...3R Set the analyzer to the appropriate function 2 Press UP or DOWN button to display RF Menu Press SELECT to display AGC MGC SET function LCD will indicate AGC Set 00 3 Press UP or DOWN button to sele...

Страница 11: ...c See Table 2 C type command response D Set Parameter Hex 1b See Table 3 D type command response RS232 RS485 Pin 1 NC Pin 1 NC Pin 2 TX Pin 2 TR Pin 3 RX Pin 3 RX Pin 4 NC Pin 4 TR Pin 5 GND Pin 5 RX...

Страница 12: ...or Binary 0 255 Major revision number equivalent to the first digit in display format 13 Firmware version minor Binary 0 255 Minor revision number equivalent to the last two digits in display format 1...

Страница 13: ...erature alarm status B0 temp low alarm B1 temp high alarm B2 temp too high alarm Laser will be shutdown when too high 3 Bias alarm status B0 Laser bias alarm 4 RF Mod Lvl Alarm status B0 RF level low...

Страница 14: ...ptical power still is lower the unit will require a factory check Contact PCT International Inc Cooling fan does not work The unit will require a factory check Contact PCT International Inc Troublesho...

Страница 15: ...S For Technical Assistance or Sales Information contact 1715 W Sunrise Blvd Gilbert AZ 85233 Phone 800 315 2253 480 813 0925 Fax 480 892 5537 www pctusa net info pctusa net All manuals and user guides...

Отзывы: