09
PCP Mobile Power Station BP9000
Instruction Manual
D
GB
1.2 LED lights while charging
Red LED is blinking:
no charging
Red LED lights continuously:
in charging process
Green LED lights up:
charging completed
2. Connecting devices with BP9000
1. Turn main switch (4)
to „O = Off“.
Note:
• Turn off the modelling light of your flash to achieve a longer battery performance.
• After switching the main switch (4) to “I=On”, the power station will run a short detection after a peep. During the detection, colours of the LEDs at control unit
will change. After a few seconds follows another peep and status LED (7) lights up green. The detection is complete and the power station is working.
• When using for outdoor photography, a waterproof housing (optional) is recommended. Make sure that the housing does not
cover the fan inlet and outlet.
V. Function Modes
1. Flash Mode
The flash mode is especially for the use with flashes. The standby function is not available in this mode.
For the use with non-flash devises please select “Normal Mode”.
Peak power: approx. 1500W for 2 seconds.
Example: 2 studio flashes à 1000Ws with recycling time of 2 seconds can be easily operated (for about 200 flashes).
Note:
When battery is empty it takes about 3 hours to fully charge the power station. Remove the cables when
charging is complete. To extend battery life please fully charge power station:
1. each time after using the power station
2. when the power station has not been used for about 100 days
2. Connect your device with one of
the 3 AC output sockets (2).
3. Turn main switch (4) to „I = On“.
4. Turn mode selection (15) to
required mode (Flash or Normal)
5. Turn on the connected
device. Now the device
draws power from
power station.
2. Normal Mode
For electric devices (except flash units) with a rated output which does not exceed 750W. The maximum power of BP9000 is 750W.
Short-term application up to 800W approx. 3 minutes. The standby function is available in this mode. If the operating voltage
exceeds 750W, the LED for output power (6) is blinking red and an alarm will be heard. At the same time, the status indicator (7)
lights up red, and the mobile power station will shut down automatically.
The power station adopts a 12Ah/12.8V LiFePO4 battery. Here are two examples, how long you can work with the fully charged power station:
• with 100W Halogen lamp, the power station can work for about 80 minutes continuously.
• with 500W Quartz light, the power station can work for about 15 minutes continuously.
Recycling time
Flash power
Recycling time with power station
1 second
up to 800Ws
no change
1 second
exceeds 800Ws
becomes longer but does not exceed 5 seconds
2-3 seconds
up to 2400Ws
no change
2-3 seconds
exceeds 2400Ws
becomes longer but does not exceed 5 seconds
3 seconds
up to 3000Ws
no change
3 seconds
exceeds 3000Ws
becomes longer but does not exceed 5 seconds