08
PCP Mobile Power Station BP9000
Instruction Manual
D
GB
2. Functions
2.1 LED indicators
LED Battery indicator (5)
LED Power indicator (6)
2.2 Mode selection (15) –refer to capture V
The mobile power station has two different operation modes:
• Flash:
Special mode for use with flashes. In this mode the standby function is not available; built-in battery can stand by for about 13 hours.
• Normal: For use with non-flash electronic devices. In this mode the standby function is available; built-in battery can stand by for about 55 hours.
Not recommended for use with flashes.
2.3 Main switch (4)
O = OFF
Power station is powered off
I = ON
Power station is powered on; ready to use
II = USB
Power station enters into USB charging mode. When LED USB indicator (10) lights up, electronics with USB interfaces
e.g. iPhone and iPad can be charged over the USB sockets (8).
USB 1
power output 5V/2000mA
USB 2
power output 5V/1000mA
USB 3
power output 5V/500mA
2.4 AC output sockets (2)
• The 3 AC output sockets are in parallel connection and each of them can output the maximum power.
• The AC outputs are universally applicable for each country, no adapter needed.
• Standard voltage: 230V/50Hz or 110V/60Hz
IV. Operation instruction
1. Installation and detachment of battery unit
LED
Battery voltage
Red, blinking
<10.7 oder > 15.4 V
Red
10.7 ~ 11.2 V
Orange
11.2 ~ 12.3 V
Green
12.3 ~ 14.6 V
Orange, blinking
14.6 ~ 15.4 V
• In loaded operation, the LED light changes when battery voltage goes down.
The higher the load power is, the more abruptly LED light changes.
• In loaded operation, the power station will shut down automatically if the power indicator (6)
blinks frequently and the buzzer alarms for over 5s. In this case, the remaining battery power is
too low to afford the current load. Please charge it for use.
LED
Output power
Off
0-35 W
Green
35~230 W
Orange
230~520 W
Red
520~670 W
Red, blinking
> 670 W
LED Status indicator (7)
LED
Status
Red
Off no working
Green
On working
Installation
• Place the control unit on
the battery unit.
• Close all 4 locks (11)
to connect the two units
together securely.
Detachment
• By pressing in the middle
of the locks, the locks can be
opened easily.
• Remove the control unit
from the battery unit.
1.1 Charging
1. Turn off power station
before charging
2. Insert the charging cable (25)
into the charging socket (17).
3. Connect the AC power cable
(27) with AC input socket (24).