3.  The colorStriker should now be connected to the device via Bluetooth to your computer. To set up the colorimeter please click on 
 

the Bluetooth icon in the bottom left of the colorStriker software. The search will automatically search for new devices. Once your 

 

Bluetooth  connection  is  activated  and  the  device  is  found,  a  window  appears  with  a  small  box  on  your  screen.  In  this  field, 

 

enter the PIN code of colorStrikers, the default setting is 0000.

4.  Now your device should have a Bluetooth connection.

2.7.2 Secondary compounds

When the device is connected to your computer via Bluetooth and the software is installed, you only need to turn on the device, as 
described above. You do this with the B button to start the software and begin to measuring. 

2.8 Reconnecting

After a period of nonuse and the device is not paired with a PC via Bluetooth it will switch off automatically. If you want to use the 
device again, press the B button, the red LED will light up. You will also need press the reconnect button in the status bar of the 
colorStriker-software in order to reconnect. 

3. Use of the colorStriker

colorStriker is a very user-friendly truecolormeter. To enjoy its use and produce accurate results, please read the following guidelines. 

3.1 Using the measurement help instrument

Included in the packaging is a measuring instrument to help obtain the optimal measuring distance. This tool will also help you 
develop a feel for the device and the type of measurements. It is designed as a cradle for the colorStriker allowing for an ideal 
measuring distance of 15 mm and a circular measuring area of 18 mm. To use, place the tool facedown on the area to be measured 
making sure it sits flat and securely on the area. Place the colorStriker on the tool. Now you can start measuring.
Press the A or B button quickly so that the white LEDs light up and the device will automatically trigger.The B button measures a 
reference value, and the A button measures your sample. To interrupt the measurement process briefly press the A or B button, you 
can then start again.
In order to become familiar with using the device you should practice measuring the same area with the both buttons. After the 
measurement, the values will be immediately visible on your screen. Moreover, acquaint yourself with the measurement using the right 
angled orientation / proper attitude of the device in hand to achieve optimal results. For as touching the device in the measurement 
with the measuring means, so the device should also be held later in the hand.

2. Commissioning / Start

Содержание ColorStriker

Страница 1: ...Commerce Way Suite 8 Jupiter FL 33458 USA From outside US 1 Tel 561 320 9162 Fax 561 320 9176 info pce americas com www pce instruments com english www pce instruments com PCE Instruments UK Ltd Units...

Страница 2: ...he LiPo cells catch fire 8 1 3 Warranty Claims Disclaimer 8 2 Commissioning Start 9 2 1 Scope 9 2 2 Product Description 9 2 3 Device overview Construction of the device 10 2 4 Applications 10 2 5 Init...

Страница 3: ...he Archive 16 4 5 Deviation Delta E E 16 4 6 Saving the data 16 4 7 Show only reference values Delta E E 16 4 8 Functions in the status bar 16 5 Functions of the software 17 5 1 How to measure the col...

Страница 4: ...e now on the market to set up device groups We are happy to present our innovative color measurement device which does not belong to these categories but represents an entirely new generation of color...

Страница 5: ...Caution Risks of danger or damage which can be cause to the device Warning Possible situations which could cause damage to the device 5 1 2 Security Please read the following instructions carefully t...

Страница 6: ...oid any warranty by the manufacturer If the shell is defective discontinue use of the device colorStriker must not be exposed to direct sunlight Please use the product at temperatures between 10 and 4...

Страница 7: ...it must be disconnected from the mains The input and output values may not exceed the values specified on the device The maximum ambient temperature is 40 C Use the device only in dry areas Do not ope...

Страница 8: ...g procedures Stay calm and secure the area Evacuate the area If possible remove all flammable objects from the danger area Do not inhale the smoke or fumes There is a risk of poisoning Do not make any...

Страница 9: ...o boundaries and allows you to archieve exact color results After the fast and accurate measurement data using the included software colorStriker presented visually and realistically on your screen an...

Страница 10: ...iddle at the bottom On the upper shell are two buttons A and B including two LEDs in red and green The device for the power unit is located at the rear of the instrument 2 4 Applications Measurement o...

Страница 11: ...ows 1 Insert the CD ROM into the drive of your computer 2 If the installation does not start automatically select setup exe 3 Follow the instructions in the setup program on the screen 2 7 Connecting...

Страница 12: ...and produce accurate results please read the following guidelines 3 1 Using the measurement help instrument Included in the packaging is a measuring instrument to help obtain the optimal measuring di...

Страница 13: ...optimal distance of 15 mm in order to gain the most accurate measurement 3 Measure at a distance of 15 mm to the object When the optimum distance is reached the device will automatically transfer the...

Страница 14: ...he following sub menus can be found Export archive data Here the full package is exported Export to Excel For separate analysis the measured data can be exported directly in to Excel From Excel 2007 E...

Страница 15: ...e option of choosing the operating language Display color spaces Shows the measured color values in six different ways CIE Lab CIEXYZ sRGB HCUC CIELSh LSh Reference sources This feature allows you to...

Страница 16: ...an see the color measured as a new reference By right clicking on the album a small pop up window with additional functions will appear You can delete the album create a new folder or create a new alb...

Страница 17: ...esired value After you have measured there is an audible tone and the measured color will appear immediately on the screen 5 2 Entering the reference values Here you can enter the reference values in...

Страница 18: ...orStriker if the unit is switched off this error message will appear Troubleshooting First click on OK and then verify that the device is turned on otherwise follow the steps in section 2 7 2 connecti...

Отзывы: