background image

Manual 

 

Specifications 

Measurement range 

Flow velocity 

0.3 … 45 m/s 

Volume flow 

0.001 ... 9999 m³/min 

Temperature 

-30 ... +60 °C / -22 ... +140 °F 

Accuracy 

Flow velocity 

±3 % + 0.1 m/s 

Temperature 

±1.5 °C / ±2.7 °F 

Resolution 

Flow velocity 

m/s: 0.01, km/h: 0.1, ft/min: 1, 
knots: 0.1 
mph: 0.1 

Volume flow 

cmm: 0.001, cfm: 0.001 

Temperature 

0.1 °C 

General technical data 

Operating / storage temperature 

-10 ... +60 °C / -14 ... +140 °F 

Max. operating humidity 

≤ 90 % RH (non-condensing) 

Sampling rate 

1 s 

Average measurement 

every 30 measurement values 

Power supply 

9 V block battery 

Auto Power Off 

after 15 minutes 

Dimensions 

185 x 66 x 33 mm (L x H x W) 

Weight 

311 g 

 

Содержание PCE-VA 10

Страница 1: ...ents UK Ltd Units 12 13 Southpoint Business Park Ensign way Hampshire Southampton United Kingdom SO31 4RF From outside UK 44 Tel 0 2380 98703 0 Fax 0 2380 98703 9 info pce instruments com www pce inst...

Страница 2: ...Manual 2 Contents 1 Introduction 3 2 Safety notes 3 3 Specifications 4 4 System description 5 4 1 Device 5 4 2 LCD 6 5 Instructions 7 6 Contact 9 6 1 PCE Instruments UK 9 6 2 PCE Americas 9...

Страница 3: ...eady for operation Moreover it is easy to operate and lightweight Delivery content 1 x PCE VA 10 1 x 9 V battery 1 x instruction manual Optional tripod 2 Safety notes Please read this manual carefully...

Страница 4: ...velocity m s 0 01 km h 0 1 ft min 1 knots 0 1 mph 0 1 Volume flow cmm 0 001 cfm 0 001 Temperature 0 1 C General technical data Operating storage temperature 10 60 C 14 140 F Max operating humidity 90...

Страница 5: ...Device 1 air velocity sensor 2 sensor interface 3 LC display 4 Set key 5 Backlight key 6 Hold key 7 speed unit selector down 8 On Off key 9 MAX MIN 10 AVG up 11 temperature unit selector 12 battery c...

Страница 6: ...elocity units m s km h ft min knots nautical miles per hour Mph 6 air velocity reading 7 air flow and area units air flow CMM cubic metres per minute CFM cubic feet per minute X100 display data x 100...

Страница 7: ...nactivity 5 After selecting the mode of measurement press the key to choose the desired unit for determination of the wind velocity 6 Press the key once to hold values The HOLD icon will appear in the...

Страница 8: ...The device will now show the following Note The unit for the area can be selected by means of the key Area indicated in square metres When the area exceeds 9999 square metres the display will show dis...

Страница 9: ...contact PCE Instruments 6 1 PCE Instruments UK By post PCE Instruments UK Ltd Units 12 13 Southpoint Business Park Ensign Way Southampton Hampshire United Kingdom SO31 4RF By phone 02380 987 035 6 2 P...

Отзывы: