Safety notes 

Please read this manual carefully and completely before you use the device for the first time. The 
device  may  only  be  used  by  qualified  personnel  and  repaired  by  PCE  Instruments  personnel. 
Damage or injuries caused by non-observance of the manual are excluded from our liability and 
not covered by our warranty. 
 

 

The device must only be used as described in this instruction manual. If used otherwise, 
this can cause dangerous situations for the user and damage to the meter. 

 

The instrument may only be used if the environmental conditions (temperature, relative 
humidity, …) are within the ranges stated in the technical specifications. Do not expose 
the device to extreme temperatures, direct sunlight, extreme humidity or moisture. 

 

Do not expose the device to shocks or strong vibrations. 

 

The case should only be opened by qualified PCE Instruments personnel. 

 

Never use the instrument when your hands are wet. 

 

You must not make any technical changes to the device. 

 

The appliance should only be cleaned with a damp cloth. Use only pH-neutral cleaner, 
no abrasives or solvents. 

 

The device must only be used with accessories from PCE Instruments or equivalent. 

 

Before each use, inspect the case for visible damage. If any damage is visible, do not 
use the device. 

 

Do not use the instrument in explosive atmospheres. 

 

The measurement range as stated in the specifications must not be exceeded under 
any circumstances. 

 

Non-observance of the safety notes can cause damage to the device and injuries to 
the user. 

 

Remove the batteries when the meter is not used for more than 60 days. 

 

Turn off the meter when not in use. 
Do not use the full measurement range. 

 

Set your meter before connecting the test leads. 

 

Before replacing the batteries or the fuse, turn off the meter and remove the test leads. 

 

Be particularly careful with voltages over 30V AC RMS, 42 V AC peak or 60V DC to 
avoid electric shocks. 

 

Make sure the test object does not carry any voltage when making a resistance or diode 
test. 

 

Do not touch the measuring tips. 

 

Always  use  personal  protective  equipment  when  measuring  live  wires  to  avoid  an 
electric arc. 

 

Do not use the meter when it no longer works flawlessly. 

 
We do not assume liability for printing errors or any other mistakes in this manual. 
 
We expressly point to our general guarantee terms which can be found in our general terms of 
business. 
 
If you have any questions please contact PCE Instruments. The contact details can be found at 
the end of this manual. 
 
 
 

 

Содержание PCE-IT100

Страница 1: ...sulation Tester User Manual User manuals in various languages fran ais italiano espa ol portugu s nederlands t rk polski can be found by using our product search on www pce instruments com Last change...

Страница 2: ...o point 8 7 Insulation measurement 8 7 1 Measuring AC motors 8 7 2 Measuring DC motors 8 7 3 Measuring insulated cables 8 8 Continuity test resistance measurement 9 9 Voltage measurement AC DC 9 10 Au...

Страница 3: ...es from PCE Instruments or equivalent Before each use inspect the case for visible damage If any damage is visible do not use the device Do not use the instrument in explosive atmospheres The measurem...

Страница 4: ...ons on the meter which mean the following This icon can be found next to another symbol or a connection and is a reference to the user manual This icon indicates that high voltage could be present Sho...

Страница 5: ...ts in commercial buildings Motors switches sub distributors in a three phase circuit light circuits in commercial buildings supply cables for industrial plants electrical appliances or connections nea...

Страница 6: ...0 00 400 0 Resolution 0 01 0 1 Accuracy 1 2 3 digits Overvoltage protection 250 V RMS Measuring voltage max 5 8 V Continuity test Icon Resolution 0 01 Audible signal 35 Short circuit current 200 mA Ov...

Страница 7: ...ment at 250 V 0 10 Measurement range 0 250 4 000 M 4 001 40 00 M 40 01 400 0 M 400 1 4000 M Resolution 0 001 M 0 01 M 0 1 M 1 M Accuracy 2 10 digits 2 10 digits 5 5 digits 4 5 digits Test current 1 mA...

Страница 8: ...st Audible signal at resistance 35 Battery indication is displayed when battery voltage is no longer sufficient Excess of measurement range OL is displayed Sampling rate 2 5 measurements s 0 4 Hz Zero...

Страница 9: ...truments 7 4 Device description 1 LCD 2 MAX MIN HOLD key 3 LOCK key 4 Zero point and backlight key 5 TEST key 6 Rotary function switch 7 V input jack 8 Ground input jack 9 Strap holder 10 Battery comp...

Страница 10: ...sent in the meter The reading will be shown in the upper part of the display The test voltage is shown in the lower part of the display The measurement range is selected by the meter automatically Not...

Страница 11: ...es of inactivity This function cannot be disabled To turn on the meter again after auto power off turn the rotary switch back to OFF and then turn it o the desired position 11 Keys The meter has four...

Страница 12: ...ttery compartment at the rear side the cover of which is affixed with four screws Remove all batteries You can now replace the fuse Only use an FF 500 mA 1000 V fuse 15 Warranty You can read our warra...

Страница 13: ...583 975 114 Fax 49 0 2903 976 99 9971 Fax 44 0 2380 98703 9 Fax 39 0583 974 824 info pce instruments com info pce instruments co uk info pce italia it www pce instruments com deutsch www pce instrumen...

Отзывы: