1.3.

 

Specification

 

1.3.1.

 

Mechanical Index of Rebound Apparatus 

Metrological verification specifications: 

Verification Regulations of Rebound Apparatus 

(JJG_817-2011)

 

Impact energy:

 

0.225kgm (2.207J±0.100J), for testing ordinary building and 

bridge construction

 

Rigidity of recoiling tension spring:

 

785±30.0N/m

 

Length of pointer:

 

20.0±0.2mm

 

Friction of pointer:

 

0.65±0.15n

 

Spherical radius of recoiling rod:

 

R25±1.0

 

Active length of recoiling tension spring:

 

61.5±0.3mm

 

Impact length of recoiling rod:

 

75.0±0.3 mm

 

Initial bouncing position of recoiling hammer:

 

graduated scale“0”+1

 

Calibration value on steel anvil:

  

80±2 

 

Graduating position “100” of shell calibration:

 

overlap with the side of positioning gap 

of calibrator cover plate of the rebound apparatus. 

 

Consistency of test indicating value:

 

±1

 

Operating Temperature: 

 

-4º

C

-+40º

C

 

1.3.2.

 

Appliance Indexes 

Display screen:

 

high-light blue OLED display screen

 

Resolution:

 

256X64

 

Mass Memory:

 

Maximally can store components: 1000

 

Maximum number of testing zones:

 

16

 

Maximum number of test points in a testing zone:

 

16 times

 

National unified curve:

 

1

 

Customized curve:

 

 

Battery:

 

can charge high-capacity Li-ion battery

 

Data interface:

 

Mini-USB interface

 

Types of sensor:

 

non-contact optical coupler type sensor

 

Strength unit: 

 

Mp, N/mm

2

, Kgf/ mm

2

 

Communication mode:

 

serial port communication, wireless communication (optional)

 

1.4.

 

Parameter Specification

 

Test times (test point), for each test point in each testing zone, according to 

Regulations

the test times are 16.

 

Testing  zone,  a  test  unit  for  testing  concrete  compressive  strength  of  structure  or 
component, with an appropriate area no more than 0.04

.

 

Equivalent value of concrete strength in testing zone refers to the concrete compressive 
strength  value  of  the  tested  unit  calculated  based  on  the  average  rebound  value  and 
carbonization depth of testing zone via strength-measuring curve. 

 

Test angle, casting surface, if the rebound apparatus is not in horizontal direction or the 
tested surface is non-concrete casting side, after setting the test angle and casting surface 
respectively,  the  apparatus  can  automatically  conduct  angular  correction  and  casting 
surface correction of rebound value. 

 

 

 

Содержание PCE-HT 224E

Страница 1: ...pce americas com PCE Instruments UK Ltd Unit 11 Southpoint Business Park Ensign way Hampshire Southampton United Kingdom SO31 4RF From outside UK 44 Tel 0 2380 98703 0 Fax 0 2380 98703 9 info pce inst...

Страница 2: ...3 2 1 3 Setting the number of test zone 11 3 2 2 Test zone setup 12 3 2 2 1 Setting test angle 12 3 2 2 2 Setting poured surfaces 12 3 2 2 3 Setting carburized depth 12 3 2 2 4 Setting strength curve...

Страница 3: ...ta collection without changing the original physical structure of mechanical rebound apparatus in which way the optical coupler sensor has no contact nor friction with the mechanical part of rebound a...

Страница 4: ...guide bar 10 Hammer mass 11 Guide sleeve 12 Two part ring 13 Felt washer 14 Impact plunger 15 Cap 16 Retaining spring 17 Impact spring 18 Housing Aluminum ring 19 Housing upside 20 Pointer piece 21 Se...

Страница 5: ...ing zones 16 Maximum number of test points in a testing zone 16 times National unified curve 1 Customized curve 2 Battery can charge high capacity Li ion battery Data interface Mini USB interface Type...

Страница 6: ...at used for the rebound strength value achieved by completing testing zone or structure test According to the set parameters rebound value is corrected accordingly and then the strength result is calc...

Страница 7: ...30 upward casting surface is top surface If the angular correction value is 2 8 then the corrected rebound value is 21 2 if the angular correction value is 2 1 then the corrected rebound value is 23 3...

Страница 8: ...that is customized measuring mode such as the test times are less than 16 Calculation of average rebound value of testing zones After the testing maximum and minimum values are not taken out only con...

Страница 9: ...g curve can be modified After modification choose ok to exit and the apparatus will save the corrected content automatically 1 6 2 Testing zone is completed If the recoiling times reach the set test t...

Страница 10: ...2 Button Description...

Страница 11: ...measuring from the menu and press to enter measuring mode In this mode you can take measurement 3 2 Test mode setup Select Test mode setup from the menu and press to enter test mode setup interface 3...

Страница 12: ...t 3 2 1 2 Setting the number of test time In the interface of new part use upward and downward buttons to select Test time and press Enter button to enter setting interface Press and to adjust the num...

Страница 13: ...e parameter interface of new test zone use upward and downward buttons to select pouring surface and click Enter button to set pouring surface There are a total of 3 surfaces available Top surface Bot...

Страница 14: ...he parameter interface of test part After selection the default carburized depth of each test zone is the same as that of this test part The carburized depth of each test zone can be modified in the p...

Страница 15: ...er main menu select Test mode setup and press to enter test mode setup interface Select Re testing the current zone and press to re test the current zone The test no will return to 0 3 2 4 Basic Measu...

Страница 16: ......

Страница 17: ...nu 1 Exit from current menu and enter measuring interface 2 Re view part data review the results of completed test parts 3 Re view zone data review the results of completed test zones Enter Re view zo...

Страница 18: ...Data transfer Click Enter button to go to main menu Then select Data transfer and click Enter to enter Data transfer menu Before creating communication between instrument and PC use USB cable to conne...

Страница 19: ...er limit setup Set up upper lower limit of rebound value 00 60 Press and to change the number then press to save 3 6 4 Rights management In this menu user can enable disable and change password for th...

Страница 20: ...Press to move cursor to next number press to change current number from 0 to 9...

Страница 21: ...g interface in 30 power consumption in this mode the instrument could work 13 16 hours after fully charging In power saving measuring modes press to switch to normal measuring interface press again an...

Страница 22: ...3 6 8 Battery power Show the percentage of battery capacity 0 100...

Страница 23: ...the completion interface of test part and the measurement for the current test part is completed The completion interface of test part contains Review test part result Review test zone result New par...

Страница 24: ...wed After maintenance calibration test shall be conducted according to the requirements and the calibration value shall be 80 2 5 Introduction of PC software Thedata communication software is designed...

Страница 25: ......

Страница 26: ...n the desktop automatically Double click the shortcut to run the program The main interface of the software is a standard windows form containing the title bar menu bar and toolbar Please note After r...

Страница 27: ...ocess pointer block 22 shakes moves up to a certain place and stops there pointer block 22 rubs or bumps spring back hammer body 7 File the upper surface or two shoulders of pointer block 22 appropria...

Страница 28: ...The shock surface of recoiling hammer mass 10 is dirty Clean the dirt on casting surface 5 The friction between recoiling hammer mass 10 and central guide rod increases Wipe the hammer guide bar 9 wi...

Страница 29: ...28 2 29 1 31 17 6 18 9 19 6 21 0 24 9 28 2 29 1 30 0 30 9 32 19 1 20 8 21 2 22 7 26 5 29 8 30 7 31 6 32 5 33 20 8 22 0 22 7 24 3 28 2 31 6 32 5 33 5 34 4 34 22 4 23 6 24 5 26 0 30 0 33 3 34 2 35 2 36...

Отзывы: