4.
Maintenance
For rebound apparatus, when one of the following situations occurs, routine maintenance
shall be conducted:
⚫
Recoiling is over 2000 times
⚫
Be skeptical about the test value
⚫
Constant value of steel anvil rate is unqualified
Common maintenance methods shall fulfill the following requirements
⚫
After getting the recoiling hammer off, get out the internal machine, and
remove recoiling rod (get out the inside buffer spring) and triple unit (including
recoiling hammer, recoiling tension spring and tension spring base)
⚫
Clean all components and parts of the internal machine with gas, especially for
central guide rod, inner bore and shock surface of recoiling hammer and
recoiling rod. After cleaning the central guide rod, wipe it with a thin layer of
watch oil, while other components and parts shall not be wiped with oil.
⚫
Clean the internal wall of shelf, remove graduated scale, and the frictional force
of inspection pointer shall be 0.5-0.8N
⚫
Can not rotate the zero setting screw fixed on tail hood
⚫
Self-made or changing components and parts are not allowed
⚫
After maintenance, calibration test shall be conducted according to the
requirements, and the calibration value shall be 80±2
5.
Introduction of PC software
Thedata communication software is designed for reading and processing the data of test
part of the concrete test hammer. It can read the data of measured test part from the
digital concrete test hammer, store the data in the computer, generate a report for the
data of test part and print the report.
System requirement:
A PC with USB port
Windows XP, Windows 7, Windows 8, NetFramework 2.0
5.1.
Connect PC and hammer
Before using PC software, please do the following steps to start communication between
PC and hammer.
1. Connect PC and hammer using USB cable supplied with new instrument.
2. Power on the concrete test hammer, press
to enter main menu, then select Data
transfer
→
Data transfer mode
→
Cable
3. Select Data transfer
→
Send to PC,
“
Transferring
”
will be displayed on LCD and
transmission is started.
5.2.
Driver installation
Computer will prompt "Found new hardware" while the digital hammer is connected to
the computer first time, please install the driver located in X:\Drivers folder. (X: means
CDROM drive letter).
5.3.
Software Installation
Install "Digital Rebound Hammer" software
Double click "Setup\setup.exe"