Become familiar with these instructions before operating the FT-20.
3.1
HYDRAULIC POWERPAK SETUP PROCEDURE AND OPERATION
See Section 6.0 for parts identification.
Conduct the following procedures BEFORE actuation:
1. Remove the pipe plug and attach the main air hose quick disconnect to the air inlet fitting. The air supply must
be clean and dry, and 90 to 120 psi at a minimum flow of 20 cfm.
NOTE: Clean the top plate of the pump before removing the filler cap and dipstick to prevent
contaminants from entering the oil supply.
2. Remove the shipping plug from the reservoir fill port and replace with the supplied vented cap.
3.
The fill line on the reservoir is 5/16 inch from the top.
Visually inspect the oil level in the reservoir. When
operating, make sure the reservoir vented cap is in place. The oil level should be within 5/16 inch of the filler
plug; if the pump is to be operated with the reservoir unvented, the oil level should be 3/4 inch from the filler
plug. If the oil level is low, replenish the hydraulic fluid per the instructions in Section 4.3.
4. Inspect all threads and fittings for signs of wear or damage and replace them if necessary.
5. Uncoil the hose assembly from the puller unit to be used and inspect all threads, couplings, and hoses for
damage and degradation. Replace if necessary.
6. Remove the dust caps from the
hydraulic fittings of the FT-20 and
puller unit hose, and clean both couplers
prior to connecting to prevent
contaminants from entering the oil
supply. Thread the hydraulic hose
coupler from the puller unit to the quick
hydraulic coupler of the PowerPak.
NOTE: Ensure that the couplers on
both the PowerPak and hose fittings
are pushed firmly together, then
completely screwed together. Failure
to do so will prevent the oil from
returning to the pump when the
trigger is released. This will cause
the puller unit to stay in the retracted
position.
7. Clean, then connect the two air quick
disconnects from the puller unit to the
coupler plug and coupler socket of the
PowerPak.
Main Air
Supply Quick Connect
Air Quick
Couplers
Pump Quick
Hydraulic Coupler
Trigger
Response Valve
Figure 3.1-1
FT-20 PowerPak