NMS044 Reference Manual Rev E
Configuring LD Settings for the RV50X
A-15
Step 18
Navigate to the
I/O
tab, and select the
Configuration
section in the left
pane.
Step 19
Verify that the settings are as shown in
Figure A-14
, and click
Apply
.
FIGURE A-14
I/O
TAKE NOTE
After this change you will not be able to connect to the gateway with a
wired Ethernet connection. If you need to restore the wired connection
without connecting to the gateway through the cellular connection, do
a hard reset on the gateway. This resets all items to the factory defaults.
As a result, you will need to configure the gateway again from step 1.
Step 20
Navigate to the
LAN
tab, and select the
Ethernet
section in the left pane.
Step 21
In the
Ethernet Port Configuration
section, change the
Ethernet Port
1 State
to
Disable
, and click
Apply
.
FIGURE A-15
LAN Settings
Step 22
In the top right of the screen, click the
Reboot
button. The gateway
saves your settings and reboots.