background image

1

1

2

2

3

3

4

4

A

A

B

B

DWG. NO.

SCALE:

SHEET

DRAWN

CHECKED

ENGINEER

TITLE

UNLESS OTHERWISE SPECIFIED TOLERANCES ARE:

DIMENSIONS IN MILLIMETERS

[ IN BRACKETS ]

ANGLES

  

`

 .5 DEGREES

24350 Indoplex Circle, Farmington Hills,MI 48335
(716)  684-0001 E-MAIL:  [email protected]

DIMENSIONS  IN INCHES

ANGLES

  

`

 

.5 DEGREES

FILLETS AND RADII 

.015 MAX 

FILLETS AND RADII 

0.38 MAX

OUTLINE DRAWING

27193

1 OF 1

FULL

MODEL 8162

SIGNAL CONDITIONER

SAC

05.24.13

DECIMALS     XX   ±.01

XXX   ±.005

DECIMALS    X   ± 0.3

XX   ± 0.13

2

7

1

9

3

PCB Load & Torque Inc. claims proprietary rights  in 
the  information disclosed hereon.  Neither it nor any 
reproduction thereof will be disclosed to others without
the written consent of PCB Load and Torque Inc.

REVISIONS

REV

DESCRIPTION

ECO

A

UPDATED TO PCB L&T - 05.24.13, PTE

41446

2.23

[56.5]

2.15

[54.6]

.81

[20.6]

5.36

[136.1]

3.70

[94.0]

2.55

[64.8]

4 X 

n

.19 [4.8]

MOUNTING HOLES

1.97

[50.0]

3.11

[79.0]

.75
[19.1]
HEX
TYP BOTH ENDS

PTE

05.24.13

SAC

05.24.13

Содержание 8162-011A

Страница 1: ...ignal Condition Installation and Operating Manual For assistance with the operation of this product contact PCB Piezotronics Inc Toll free 800 828 8840 24 hour SensorLine 716 684 0001 Fax 716 684 0987...

Страница 2: ...repair User servicing or repair is not recommended and if attempted may void the factory warranty Calibration Routine calibration of sensors and associated instrumentation is recommended as this helps...

Страница 3: ...ry customer service representative Warranty All equipment and repair services provided by PCB Piezotronics Inc are covered by a limited warranty against defective material and workmanship for a period...

Страница 4: ...isclosure Table Pb Hg Cd Cr VI PBB PBDE O O O O O O PCB X O O O O O O O O O O O X O O O O O O O O O O O O O O O O O O O O O O O O O X O O O O O O O O O X O O O O O O O O O O O X O O O O O X O O O O O...

Страница 5: ...e O O X O O O Wires O O O O O O Cables X O O O O O Plastic O O O O O O Solder X O O O O O Copper Alloy Brass X O O O O O This table is prepared in accordance with the provisions of SJ T 11364 O Indica...

Страница 6: ...er Cabling 2 4 0 Analog Outputs 2 5 0 Transducer Excitation 2 6 0 Calibration 3 7 0 Gain Switches 4 8 0 Mounting 4 Figures 1 Series 8162 Signal Conditioner 2 2 Mounting Hole Dimensions 4 3 Exterior Di...

Страница 7: ...terminal J1 Reference Figure 4 for the J1 terminal location Tighten the screw to fasten the wire in place d Next insert the Ground wire into the screw 2 position on terminal J1 Tighten the screw to f...

Страница 8: ...alue of mechanical input The calibration can then be transferred to the installed calibration resistor for convenience in checking later b Replace the installed calibration resistor with one supplied...

Страница 9: ...t Sensitivity mV V Vexc 5 VDC Sensitivity mV V Vexc 10 VDC SW2 Settings 1 2 3 4 SW2 1 SW ON 7 0 to 11 0 3 5 to 5 5 0 0 0 1 4 6 to 7 0 2 3 to 3 5 0 0 1 0 3 0 to 4 6 1 5 to 2 3 0 1 0 0 2 0 to 3 0 1 0 to...

Страница 10: ...nside View J1 Input Power J3 Output Connections P2 Voltage Output P1 Bridge Excitation SW1 RCAL Switch SW2 Gain Switch 1 RCAL R5 4mA adjust 20mA adjust R22 Fine Span R23 Coarse Zero J2 Transducer Conn...

Страница 11: ...56 6 mm x 94 0 mm x 64 8 mm Electrical Connector input output screw terminal screw terminal All specifications are at room temperature unless otherwise specified In the interest of constant product i...

Страница 12: ...NE DRAWING 27193 1 OF 1 FULL MODEL 8162 SIGNAL CONDITIONER SAC 05 24 13 DECIMALS XX 01 XXX 005 DECIMALS X 0 3 XX 0 13 27193 PCB Load Torque Inc claims proprietary rights in the information disclosed h...

Отзывы: