background image

Materials Authorization (RMA) 
Number. This RMA number should be 
clearly marked on the outside of all 
package(s) and on the packing list(s) 
accompanying the shipment. A detailed 
account of the nature of the problem(s) 
being experienced with the equipment 
should also be included inside the 
package(s) containing any returned 
materials. 
 
A Purchase Order, included with the 
returned materials, will expedite the 
turn-around of serviced equipment. It is 
recommended to include authorization 
on the Purchase Order for PCB to 
proceed with any repairs, as long as they 
do not exceed 50% of the replacement 
cost of the returned item(s). PCB will 
provide a price quotation or replacement 
recommendation for any item whose 
repair costs would exceed 50% of 
replacement cost, or any item that is not 
economically feasible to repair. For 
routine calibration services, the Purchase 
Order should include authorization to 
proceed and return at current pricing, 
which can be obtained from a factory 
customer service representative. 
 

Warranty

 – All equipment and repair 

services provided by PCB Piezotronics, 
Inc. are covered by a limited warranty 
against defective material and 
workmanship for a period of one year 
from date of original purchase. Contact 

PCB for a complete statement of our 
warranty. Expendable items, such as 
batteries and mounting hardware, are not 
covered by warranty. Mechanical 
damage to equipment due to improper 
use is not covered by warranty. 
Electronic circuitry failure caused by the 
introduction of unregulated or improper 
excitation power or electrostatic 
discharge is not covered by warranty. 
 

Contact Information

 – International 

customers should direct all inquiries to 
their local distributor or sales office. A 
complete list of distributors and offices 
can be found at www.pcb.com. 
Customers within the United States may 
contact their local sales representative or 
a factory customer service 
representative. A complete list of sales 
representatives can be found at 
www.pcb.com. Toll-free telephone 
numbers for a factory customer service 
representative, in the division 
responsible for this product, can be 
found on the title page at the front of this 
manual. Our ship to address and general 
contact numbers are: 
 
PCB Piezotronics, Inc. 
3425 Walden Ave. 
Depew, NY 14043 USA 
Toll-free: (800) 828-8840 
24-hour SensorLine

SM

: (716) 684-0001 

Website: www.pcb.com 
E-mail: [email protected] 

 
 
 
 
 
 
 
 
 
 

 
 

DOCUMENT NUMBER:  21354 
DOCUMENT REVISION:  B 
ECN: 17900 

Содержание 3741D4HB200G

Страница 1: ...ROMETER Installation and Operating Manual For assistance with the operation of this product contact PCB Piezotronics Inc Toll free 800 828 8840 24 hour SensorLine 716 684 0001 Fax 716 684 0987 E mail...

Страница 2: ...id the factory warranty Calibration Routine calibration of sensors and associated instrumentation is recommended as this helps build confidence in measurement accuracy and acquired data Equipment cali...

Страница 3: ...warranty against defective material and workmanship for a period of one year from date of original purchase Contact PCB for a complete statement of our warranty Expendable items such as batteries and...

Страница 4: ...ion The sensor element is electrically connected in a Wheatstone bridge circuit The integral amplifier provides a low impedance output to follow on instrumentation These particular accelerometers prov...

Страница 5: ...s 10 ft or 120 in 3 m Custom cable length requirements should be specified at time of ordering When applications involve very long cable runs the user is advised to take into consideration the added r...

Страница 6: ...Mounting Base This method involves attaching a base to the test structure then securing the sensor to the base This allows for easy removal of the accelerometer Contact the PCB factory representative...

Страница 7: ...es to reduce the effects of EMI and RFI that is present near electrical motors and machinery Teflon jacketed cabling may be necessary to withstand corrosive environments and higher temperatures Feel f...

Страница 8: ...its provide the capability for continuous monitoring Note High sensitivity DC Accelerometers feature on board differential amplification 7 0 OPERATING NOTE Always operate the accelerometer within the...

Страница 9: ...s and costly errors Therefore in an effort to prevent the common mistakes associated with customer performed calibration this document includes a broad overview of the Back to Back Calibration techniq...

Страница 10: ...usly calibrated over the frequency and or amplitude range of interest 2 the shaker should be selected to provide minimal transverse lateral motion and minimal distortion and 3 the quality of the meter...

Страница 11: ...SERVICE See the supplement sheet contained in this manual for information on our warranty service repair and return policies and instructions When unexpected measurement problems arise call our 24 ho...

Страница 12: ......

Страница 13: ......

Страница 14: ......

Отзывы: