3 Product description
12
993x0463x-mub-en – V02
2020/03
Change of the flow line [specialist]
Dismounting of the mixing valve
1.
Take off the thermometer handles (A-2, F-2) and remove the insulating front shell.
2.
Take the group of fittings out of the insulating back shell.
3.
Dismount the mixing valve (C).
Retrofitting of the mixing valve
1.
Loosen the screw (1).
2.
Take off the rotary knob (2) from the cock rod.
3.
Loosen the screws (3).
4.
Remove the cover plate (4).
5.
Loosen the two screws (5).
6.
Remove the front plate (6).
7.
Extract the sealing bush (7) with the cock plug (8) from the housing of the mixing valve.
8.
Loosen the screws (10) on the rear side of the mixing valve.
9.
Take off the cover (9) on the rear side of the mixing valve and fix it on the other side of
the mixing valve by using the screws (10).
10.
Insert the sealing bush (7) with the cock plug (8) into the channel of the mixing valve.
11.
Screw down the front plate (6) using the screws (5).