15
(
°F:
)
The temperature settings below are examples. The temperature setting
necessary depends on the usage, the length of piping and the time of year.
*Initial factory setting is 110°F
If fixtures incorporate mixing valves, set the temperature higher than usual.
* For most residential applications, the recommended temperature setting is 120°F (50°C in °C mode) or less.
* Consult local codes for minimum operating temperatures.
90 95 100 105
110
115
120 125
130
135
140
Shower, hot water supply, etc.
Washing
dishes, etc.
High temperature
The maximum output temperature can be set
using the Operation Display. ( page 20)
(
°C (°F):
)
The temperature settings below are examples. The temperature setting
necessary depends on the usage, the length of piping and the time of year.
*Initial factory setting is 40°C (104°F)
Shower, hot water supply, etc.
Washing
dishes, etc.
High
temperature
32 35 37 38 39 40 41 42 43 44 45 46 47 48
50 55 60
(90)
(95)
(99)
(100) (102) (104) (106) (108) (109) (111) (113) (115) (117) (118) (122) (131) (140)
The maximum output temperature can
be set using the Operation Display.
( page 20)
When using
°F mode:
When using
°C mode:
Note: It's recommended that water temperature is set as low as possible to prevent scale build-up in
the heat exchanger.