9
The Condensing Gas Combi Boiler discharges condensate.
When heat from the exhaust gas is collected within the secondary heat exchanger, condensation
occurs from moisture in the exhaust gas and the resulting water is discharged from the drain pipe
(approx. 2 gallons/hour (7.5 liters/hour) maximum). It is not a water leak. Do not plug or block the
drain line as it must always be allowed to freely flow.
Note: The condensate discharged is acidic with a pH level of approximately 2-3.
A condensate neutralizer may be required by local code prior to disposal.
The Condensing Gas Combi Boiler
tends to show white steam.
After the exhaust gas passes through the
secondary heat exchanger, the low temperature
and high moisture content tends to produce
steam at the vent discharge terminal. This is a
normal occurrence.
During combustion, white
steam may often be seen.
This is normal.
Содержание GHQ-C3201WX-FF PB US
Страница 41: ...41 Memo ...
Страница 42: ...42 Memo ...