27
Turning the Unit Back On
1. Check that all drain plugs are inserted.
2. Check that all hot water fixtures
/faucets are closed.
3. Follow the procedure on page 12 “Initial operation”, steps 1 through 5.
4. Make sure that the area around the appliance is well ventilated; open a window or a door if necessary.
Then, operate the unit and verify that condensate is coming out of the drain pipe.
(During normal use of the Combi Boiler, condensate will begin to discharge from the drain pipe within 15
minutes of use. However, depending on the season and/or installation site conditions, it may take longer.)
* If water does not appear at the end of the drain line, a qualified service technician must clean the
condensate line.
After the Combi Boiler has been out of use for a long time make sure that you fill
the condensate trap with water.
This is to prevent dangerous exhaust gases from entering the building.
Failure to fill the condensate trap could result in severe personal injury or death.
(By performing step 4 as described above, the condensate trap will automatically
fill itself with water.)
Be sure to do.
DANGER