WAN Service Configuration
39
OnSite 2701A/I E1/T1 Ethernet Bridge (NTU) User Manual
5
• WAN Services
-
ITU User:
The ITU Q.933 protocol will be used. The unit will operate as the User side of the
connection.
-
ITU Both:
(NNI) The ITU Q.933 protocol will be used. The unit will operate as both the Network
and User side of the connection.
-
ANSI Network: The ANSI T1.617 protocol will be used. The unit will operate as the Network side of
the connection
-
ANSI User:
The ANSI T1.617 protocol will be used. The unit will operate as the User side of the
connection
-
ANSI Both:
(NNI) The ANSI T1.617 protocol will be used. The unit will operate as both the Net-
work and User side of the connection.
•
Management State:
Defines the current state of the DTE side LMI. Possible options are as follows:
-
Mgt_Port_DOWN
– Currently the LMI on the DTE side is DOWN
-
Mgt_Port_UP
– Currently the LMI on the DTE side is UP
•
Management Auto Start:
(Default Value: FALSE) The management Auto Start variable allows the user to
start the LMI session before any DLCI connections are created within the unit. If this variable is set to
FALSE, the LMI session will begin when the first DLCI channel is created. If this variable is set to TRUE
the LMI session will begin immediately.
•
Full Report Cycle:
(Default Value: 6) This variable represents the N391 protocol value
•
User Max Errors:
(Default Value: 3) Network side N392 protocol value
•
Net Max Errors:
(Default Value: 3) Network side N392 protocol value
•
User Error Window Size:
(Default Value: 4) User side N393 protocol value
•
Net Error Window Size:
(Default Value: 4) Network side N393 protocol value
•
T391_Value:
(Default Value: 10) This variable sets the T391 timers in seconds.
•
T392_Value:
(Default Value: 16) This variable sets the T392 timers in seconds.
Web Configuration Methods
The following documentation defines how to configure the Frame Relay Local Management Interface using
the Web Interface on the OnSite NTU.