background image

7

4.0  CONFIGURATION

The Model 1200 is equipped with four strapping options that allow config-
uration to a wide range of applications. To gain access to the internal 
straps, loosen the hex nuts on the DB-25 connectors and pry open the 
case between the plastic shell ears. Figure 2 shows the location of each 
strapping option.

Figure 2. 

Strap settings for the Model 1200/1201

4.1  DATA RATE

The data rate strap controls the rate at which data is transmitted. Adjust 
the strap to select one of the following options: 1.2, 2.4, 4.8, 9.6, 19.2, 
38.4 or external clocking. If “external clocking” is selected, the Model 
1200 will automatically match the clocking between your two synchro-
nous devices. The default setting is 9.6 Kbps.

4.2  CARRIER DETECT

The carrier detect straps allow you to determine whether the carrier is 
“constantly on” or “controlled by RTS”. By adjusting the strap, you may 
operate in switched carrier, multi-point and/or hardware handshaking 
applications. Port 1 and port 2 may be configured separately. The 
defaults setting is “on” for both ports.

Data Rate

Carrier Detect

Port 1

Port 2

38.4 kbps

19.2 kbps

9.6 kbps

4.8 kbps

2.4 kbps

1.2 kbps

External Clock

Port 1

Port 2

0 mSec

6.6 mSec

53 mSec

Constant

Port 1 Frame

Ground connects

to signal ground

Port 2 Frame
Ground connects
to signal ground

RTS/CTS Delay

Ground

Controlled

Содержание SMARTNODE 1200

Страница 1: ...USER MANUAL MODEL 1200 1201 Synchronous Modem Eliminator SALES OFFICE 301 975 1000 TECHNICAL SUPPORT 301 975 1007 P N 07M1200 C Doc 049011U Rev D Revised 1 22 08 An ISO 9001 Certi ed Company...

Страница 2: ...1 Data Rate 9 4 2 Carrier Detect 9 4 3 RTS CTS Delay 10 4 4 Ground 10 5 0 Operation 11 5 1 LED Status Indicators Model 1201 only 11 A Specifications 12 A 1 Data Rates 12 A 2 Clocking 12 A 3 Grounding...

Страница 3: ...this product shall be deemed an acceptance of these terms by the user In the event the user detects intermittent or continuous product malfunction due to nearby high power transmitting radio frequenc...

Страница 4: ...All warranty and nonwarranty repairs must be returned freight prepaid and insured to Patton Electronics All returns must have a Return Materi als Authorization number on the outside of the shipping co...

Страница 5: ...nly 2 2 DESCRIPTION Measuring only 5 3 x 2 x 1 2 inches the Patton Model 1200 is the small est self powered synchronous modem eliminator on the market All power is derived from the RS 232 data signals...

Страница 6: ...ter or device to which the Model 1200 is to be connected 3 Plug the DB 25 connectors directly into the serial ports of your RS 232 devices If you wish to extend the distance you can add cables on both...

Страница 7: ...locking is selected the Model 1200 will automatically match the clocking between your two synchro nous devices The default setting is 9 6 Kbps 4 2 CARRIER DETECT The carrier detect straps allow you to...

Страница 8: ...er to emulate either dial up or leased line modems you can set this strap at either no delay 6 6mS or 53mS Port 1 and port 2 may be con gured separately The default setting is 6 6mS for both ports 4 4...

Страница 9: ...ived from the RS 232 data and control signals there is no ON OFF switch 5 1 LED STATUS INDICATORS MODEL 1201 ONLY The Model 1201 features six front panel status LEDs that indicate the condition of the...

Страница 10: ...es and decreases for higher bit rates A 5 FUNCTIONAL Emulates half or full duplex dial up or dedicated line A 6 RTS CTS DELAY Selectable per port 0mS 6 6mS 53mS A 7 DCD Selectable per port continuous...

Страница 11: ...11 APPENDIX B BLOCK DIAGRAM Copyright 2001 Patton Electronics Company All Rights Reserved...

Страница 12: ...his product and how we can meet your prod uct needs today and in the future Web http www patton com Sales E mail sales patton com Support E mail support patton com Phone Sales 301 975 1000 Phone Suppo...