background image

 
 

 
 
 
 
 
 
 
 

Reference manual 

 

DinBox GSM/GPRS 

 

modem 

 

 
 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Bausch Datacom NV Tiensesteenweg 56 B-3360 Korbeek-Lo +3216461288  

[email protected]

 

Summary of Contents for DinBox

Page 1: ...Reference manual DinBox GSM GPRS modem Bausch Datacom NV Tiensesteenweg 56 B 3360 Korbeek Lo 3216461288 filip bausch be ...

Page 2: ...erence manual V1 0 Bausch Datacom NV 2 CAUTION ELECTRIC SHOCK HAZARD IF COVER REMOVED SERVICE BY QUALIFIED PERSONEL ONLY Document History Date Version Status Author Info 25 10 2004 V1 0 Preliminary Filip Lavaerts Creation ...

Page 3: ... 4 Environmental conditions 10 3 5 Power Supply 10 3 6 GSM GPRS module 10 4 SIM card 11 5 Ports and Connectors 12 5 1 Power Connection 12 5 2 Serial DTE Interface 13 5 3 I O Connections 14 6 LED Indicators 16 7 Watchdog functionality 17 8 Push Button 17 9 AT Command interface 18 A EC declaration of conformity 19 B Antenna 20 C RJ 45 Modular Jack 21 D ESD Protection 22 ...

Page 4: ...DinBox GSM GPRS Reference manual V1 0 Bausch Datacom NV 4 ...

Page 5: ...l GSM data to and from remote host systems GPRS connection can normally only be used if the DTE has TCP IP capability to create and send TCP IP PPP packages Thanks to the embedded TCP IP and the implementation of a Communication Control processor the DinBox GSM GPRS is for example capable of opening closing and maintaining a GPRS connection complete independently of the DTE Once the DinBox GSM GPR...

Page 6: ...nput voltage see specifications for details on voltage range This input is protected against reversed polarity with a serial diode DTE Interface The DinBox GSM GPRS modem has a RS 232 interface RJ 45 which can be connected to a computer or similar DTE device via included RJ 45 DB 9 serial cable GSM GPRS Modem The DinBox GSM GPRS modem has a Wavecom GSM GPRS module on board Connection with the GSM ...

Page 7: ... also control the 4 I O lines and will perform the necessary action when input changes are detected or when data is received to change output pins We have different basic Communication Control applications available DinBox GSM 2 input if input is changed SMS send 2 output SMS received output will be changed 1 input SMS 1 output SMS DinBox GPRS 1 input to open a socket 1 output active when the sock...

Page 8: ...mm IP40 Symmetrical DIN rail mounting according EN50 022 Green color Standard ABS Acryl Butadiene Styrene Tmax 80 C Inflammability class acc to UL 94 HB Optional PC only on special request Polycarbonate Tmax 115 C metal DIN rail clip Inflammability class acc to UL 94 V0 3 2 Connectors Antenna SMA Serial DTE RJ 45 RXD GSM DCD Power Supply x x Not Used I O connections 4 3 2 1 DTR TXD uP ...

Page 9: ... V Max conductor cross section flexible 2 5 mm Antenna Standard SMA connector Serial DTE RJ 45 8x8 Molex 3 3 Antenne Interface The GSM antenna can be mounted directly on the GSM modem via a cable depending on the application and the RF field at the local site The antenna interface connector is SMA male Frequency TX 890 915 MHz RX 935 960 MHz Impedance 50 Ohms VSWR TX Max 1 7 1 installed RX Max 1 9...

Page 10: ... reader Asynchronous mode DTE interface with speeds up to 115 200 bps RS 232 interface option Flow control RTS CTS XON XOFF and speed buffering Automatic format speed 300 to 115 200 bps sensing AT command set support Data Features GSM DATA Data circuit asynchronous transparent and non transparent up to 14400 bit s Automatic fax group 3 Class 1 and Class 2 GPRS packet Data GPRS Class 10 Coding Sche...

Page 11: ... further call setup is prevented with the exception emergency calls See the CIMI command for more details Use the CGSN command to view the Product Serial Number of the DinBox GPRS modem How to install the SIM card 1 Disconnect the power and DTE interface 2 Open the DinBox GSM GPRS housing 3 The SIM cardholder is placed between the 2 PCB connectors onto the PCB 4 Carefully slide the metal bracket t...

Page 12: ...er before connecting or disconnecting the power and or DTE plugs 5 1 Power Supply Connection PIN DC DC Always disconnect the mains power before connecting or disconnecting the power Make sure the voltage supplied to the modem is in the range of the DinBox GSM GPRS power supply specification see specifications for details on voltage range Antenna SMA Serial DTE RJ 45 RXD GSM DCD Power Supply x x No...

Page 13: ...delivered with the DinBox GSM GPRS modem Pin RJ45 Pin DB9 V 24 V 28 I O TEXT CCITT DIN EIA 1 1 109 M5 DCD O Data carrier detect 2 2 104 D2 R D O Receive data 3 3 103 D1 T D I Transmit data 4 4 108 1 108 2 S1 1 S1 2 DTR I Data terminal ready 5 5 102 E2 GND Signal ground 6 107 M1 DSR O Data set ready 7 7 105 S2 RTS I Request to send 8 8 106 M2 CTS O Clear to send 6 9 125 M3 RI O Ring indicator Outpu...

Page 14: ...t output Below you will find the different characteristics of the different I O s TTL The 4 TTL I O lines are directly connected 4 port pins of the ATMEL AVR micro controller and can be used as digital I O or ADC inputs All connections are guarded with a Transil for ESD protection See chapter D for more information Defined as Input internally connected via 20Kohm pull up to Vcc left open Æ high in...

Page 15: ...e optional possible Relais Contact Output Normal open contact default Normal closed contact optional Load Res load p f 1 Induct load p f 0 4 L R 7 ms Rated load 0 5 A at 125 Vac 1 A at 24 Vdc Max operation voltage 125 Vac 60 Vdc Max operation current 1 A Vcc To processor 1 K BAS16 1 3 2 4 SFH6156 2 0 E 1 3 2 4 From processor NO NC ...

Page 16: ... Data DTE Æ DCE Reflects the state of the TXD signal RXD Receive Data DCE Æ DTE Reflects the state of the RXD signal DTR Data Terminal Ready DTE Æ DCE Reflects the state of the DTR signal DCD Data Carrier Detect DCE Æ DTE Reflects the state of the DCD signal µP PD6 Onto PCB internal µP PB7 µP PB6 WD Watchdog Tick Reflects the state of the Watchdog Communication control processor µP micro processor...

Page 17: ... period is ended and the modem is connected to a remote host active DCD signal the reset will not be conducted If the reset period is ended and the watchdog already past a reset because of an active DCD signal the reset will be conducted after 10 minutes Otherwise if the DinBox GSM GPRS is locked up with an active DCD signal the watchdog will never be able to reset the WAN module 8 Push button The...

Page 18: ... on the Wavecom Wismo Q2403 module The original Wavecom manuals are available onto the CD ROM Two manuals are available AT Commands Interface Guide This manual describes the AT commands based messages exchanged between an application and the DinBox GPRS modem in order to manage GSM related events or services AT Commands Interface Guide for IP Connectivity DinBox GPRS version only This manual descr...

Page 19: ...DinBox GSM GPRS Reference manual V1 0 Bausch Datacom NV 19 A EC Declaration of conformity ...

Page 20: ...DinBox GSM GPRS Reference manual V1 0 Bausch Datacom NV 20 B Antenna Dual band GSM antenna Frequency 880 1880 MHz Gain 0 dB RG 174 cable 250 cm with FME plug female ...

Page 21: ...DinBox GSM GPRS Reference manual V1 0 Bausch Datacom NV 21 C RJ 45 Modular Jack ...

Page 22: ...DinBox GSM GPRS Reference manual V1 0 Bausch Datacom NV 22 D ESD protection ...

Reviews: