manualshive.com logo in svg
background image

 

70-00121-01-00 

Proprietary Redline Communications © 2009 

 

Page 1 of 34

 

October 20, 2009 

 
 

 

 
 

 

 

 

 

Outdoor Wireless Access 

Subscriber Modem 

REM Series 

 

User Manual 

Содержание RedMAX 4C REM2500M

Страница 1: ...70 00121 01 00 Proprietary Redline Communications 2009 Page 1 of 34 October 20 2009 Outdoor Wireless Access Subscriber Modem REM Series User Manual ...

Страница 2: ...ions com Sales Inquiries North American nainfo redlinecommunications com Toll free sales 1 866 633 6669 International intlinfo redlinecommunications com Support www redlinecommunications com support support_portal html Document Control 70 00121 01 00 4C_SS_Outdoor_REM_UserManual 20090914a doc Disclaimer The statements configurations technical data and recommendations in this document are believed ...

Страница 3: ...3 Unit Features 13 3 1 1 Ethernet Port and Cable 14 3 1 2 Grounding Connection 15 3 1 3 PoE Power over Ethernet Power Adaptor 15 4 CLI Commands 16 4 1 Local Ethernet Port IP 16 4 2 Telnet Access 16 4 2 1 Login 16 4 2 2 Logout 16 4 3 Modes and Commands 16 4 3 1 bsidtable Base Station ID Table 18 4 3 2 buzzer Antenna alignment Tool 19 4 3 3 collectradio Radio Statistics 19 4 3 4 ethtag Ethernet Tagg...

Страница 4: ...Act LEDs 15 Table 6 CLI Generic Commands 17 Table 7 CLI Modes and Commands 17 Table 8 CLI bsIdTable Base Station ID Table Commands 18 Table 9 CLI buzzer Antenna Alignment Tool Commands 19 Table 10 CLI collectradio Radio Statistics 19 Table 11 CLI ethTag Ethernet Tagging Commands 20 Table 12 CLI interface Ethernet and Wireless Configuration Commands 21 Table 13 CLI loadImage Upgrade CPE Software Co...

Страница 5: ...lure to comply with these requirements 1 2 Important Warning Symbols The following symbols may be encountered during installation or troubleshooting These warning symbols mean danger Bodily injury may result if you are not aware of the safety hazards involved in working with electrical equipment and radio transmitters Familiarize yourself with standard safety practices before continuing Electro Ma...

Страница 6: ... electrical power circuits 9 The system must be properly grounded to protect against power surges and accumulated static electricity It is the user s responsibility to install this device in accordance with the local electrical codes correct installation procedures for grounding of the outdoor unit mast lead in wire and discharge unit location of discharge unit size of grounding conductors and con...

Страница 7: ...from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help FCC Caution Any changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate this equipment This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not c...

Страница 8: ...ata Transmission Systems operating in the 2 500 MHz to 2 690 MHz frequency band Part 1 TDD Base Stations Harmonized EN covering the essential requirements of article 3 2 of the R TTE Directive EN 302 326 2 REM3500M 3 5 GHz systems Only Fixed Radio Systems Multipoint Equipment and Antennas Part 2 Harmonized EN covering the essential requirements of article 3 2 of the R TTE Directive for Digital Mul...

Страница 9: ... verklaart naam van de fabrikant dat het toestel type van toestel in overeenstemming is met de essentiële eisen en de andere relevante bepalingen van richtlijn 1999 5 EG Malti Maltese Hawnhekk isem tal manifattur jiddikjara li dan il mudel tal prodott jikkonforma mal ħtiġijiet essenzjali u ma provvedimenti oħrajn relevanti li hemm fid Dirrettiva 1999 5 EC Magyar Hungarian Alulírott gyártó neve nyi...

Страница 10: ...l responsibility for the system security is the responsibility of the system administrator and operators 1 9 WEEE Product Return Process In EU countries dispose of equipment in accordance with the WEEE Waste from Electrical and Electronic Equipment directive 2002 96 EC Redline Communications equipment is marked with the logo shown above The WEEE directive seeks to increase recycling and re use of ...

Страница 11: ...rriers to individual users allowing simultaneous transmission from several users OFDMA uses the Fast Fourier Transform FFT algorithm to implement modulation and demodulation functions Using adequate channel coding and bit interleaving OFDMA can perform very well in severe multipath environments mitigate frequency selective fading and provide high spectral efficiency 2 4 Convolutional Turbo Codes a...

Страница 12: ...hile avoiding frequency contention in adjacent sectors 2 9 Service Flows A Service Flow represents a unidirectional data flow with separate QoS settings for uplink and downlink Service flows provide the ability to set up multiple connections to each subscriber in a sector Separate service flows can be established for uplink and downlink traffic where each service flow is assigned a unique service ...

Страница 13: ...k The subscriber is a fully integrated unit with a built in Multiple Input Multiple Output MIMO antenna system Power is supplied by Power Over Ethernet PoE The subscriber electronics are housed in a weatherproof aluminum alloy case Figure 1 Subscriber System Features Table 3 Subscriber Installation Parts Included with system Items sold separately 1 Subscriber with integrated antenna 2 Power over E...

Страница 14: ...e is a passive Ethernet device and does not amplify or repeat signal The maximum total length of the Ethernet cable is 100 m 328 ft For example 98 m from the REM to the PoE and 2 m from the PoE to the connected network equipment The indoor end of the Redline supplied outdoor hardened CAT 5 Ethernet cable is terminated with a standard indoor RJ 45 connector for connection to a PoE power adaptor CO ...

Страница 15: ...one AC powered device Important PoE Equipment The Ethernet outdoor cable is supplying a protective ground connection for the Ethernet cable Customer supplied PoE devices e g central office switches equipped with RJ 45 sockets that provide PoE power and data must have metal lined RJ 45 sockets providing a protective ground connection to the cable shield Redline Supplied PoE Power Adapter The Redlin...

Страница 16: ...gin Type telnet followed by the IP address of the subscriber system depress ENTER and enter the account and password when prompted Username admin Password admin 4 2 2 Logout Exit from a CLI session by typing logout ENTER The system prompts for logout confirmation Depress Y to complete the logout process Note To exit from the Telnet session you must be in the root directory Go to the root directory...

Страница 17: ...elp command ENTER help command parameter ENTER Table 7 CLI Modes and Commands Command Description bsidtable Access the Management Base Station ID table buzzer Audible alignment tool if hardware equipped collectradio Display radio statistics ethtag Display modify the Ethernet Tagging eventlog System event log interface Configure Ethernet and wireless interfaces loadimage Download and run a new soft...

Страница 18: ...ble optional Example Use the following command to register a base station with priority 2 in the fourth position in the table CPE bsId add 00 09 02 00 a3 5d priority 2 3 Enter delete entrynumber all yestoall Delete a base station ID entry If the table position value is not specified the last entry in the table is deleted The count value is adjusted to reflect the current number of entries Confirma...

Страница 19: ...t tool 0 Disable buzzer 1 Enable buzzer show Display status of audible alignment tool Buzzer is turned off Buzzer is turned on Buzzer is not present on this platform 4 3 3 collectradio Radio Statistics Collect and display information about the radio Important This command produces machine readable output only Table 10 CLI collectradio Radio Statistics collectradio get time Specify radio collection...

Страница 20: ...ging mode 0 Disabled All tagging features are disabled 1 Enabled Each upstream packet received on the subscriber Ethernet port is tagged with the specified VID value field If the packet has an existing VLAN tag a new outermost tag is added Q in Q The modified packet is forwarded over the wireless interface to the base station priority 0 7 Default priority for VLAN tagged packets value VLAN ID This...

Страница 21: ...20 33 mask 255 255 255 0 yes port auto duplex speed Ethernet port settings auto 0 1 Set negotiation mode 0 Disable auto detect speed and duplex See speed and duplex 1 Enable auto detect speed and duplex Ignore speed and duplex duplex 0 1 Set Ethernet port duplex 0 Operate at half duplex mode only 1 Operate at full duplex mode only speed 0 1 Set Ethernet port speed 0 Operate at 10Base T only 1 Oper...

Страница 22: ...control is active csublayer 0 2 View and modify the wireless interface convergence sublayer settings 0 IPCS NAT 1 EthernetCS 2 IPCS phy bandwidth framesize View and modify the wireless interface physical layer settings bandwidth 5000 7000 8750 10000 Channel size Hz 5000 5 MHZ 7000 7 MHZ 8750 8 75 MHZ 10000 10 MHZ framesize 5000 10000 Frame duration microseconds 5000 5 000 us 10000 10 000 us Show c...

Страница 23: ...s The command will prompt for the following information ServerIP IP address of FTP server Filename Name of the binary file Must be located in the FTP default directory Example CPE loadImage Server IP Address 192 168 100 100 File Name REM 18 M 001 02 02 005 bin Opening FTP connection Done Downloading image Done Programming update Done Erasing setup partition Done Writing setup partition Done Erasin...

Страница 24: ...riorityn 0 9 Priority for this frequency interval n 1 16 hirffreqn 1800 1830 High frequency KHz for this frequency interval n 1 16 Example CPE rfconfig set hirffreq1 1810000 lorffreqn 1800 1830 High frequency KHz for this frequency interval n 1 16 maxrngretries 1 5000 Max number of retries for initial ranging maxtxpower value Maximum Tx power dBm Refer to specifications nomadic 0 1 Set the nomadic...

Страница 25: ...he entire scan for all non zero ranges If all ranges are zero the subscriber will scan the entire range of the radio During the scan the subscriber compiles a table of detected base stations filtered by the bsidtable entries and orders the results based on priority and then signal level CINR Once the scan is completed the table is saved in non volatile RAM preserved through subscriber reboot power...

Страница 26: ...lay current statistics values CPE statistics eap show inPackets 0 outPackets 0 eapStart 0 eapIdRequest 0 eapIdReply 0 eapSuccess 0 eapFail 0 ineapTlsPackets 0 outeapTlsPackets 0 outeapAuthKeys 0 badeapAuthKeys 0 eaplastidxReq 0 forwarder show Packet forwarder statistics show Display packet forwarder statistics CPE statistics forwarder show FORWARDER SYNTHESIS Interface Packets Loss unit packet TO ...

Страница 27: ...Packet 2461 OutBytes 0 wman0 show Wireless interface statistics clear Reset all counters to zero show Display current statistics values CPE statistics interface wman0 show Settings Wman statistics InPacket 0 InBytes 0 OutPacket 0 OutBytes 0 packetflows show Packet based statistics show Display current statistics values CPE statistics packetflows show PACKET FLOW SYNTHESIS Module Input Output Loss ...

Страница 28: ...errors dlmaperrcount downlink map semantic errors dlmpducount downlink MAC packet data units sent received dlsducount downlink MAC service data units received downlink show all fields of downlink group frameduration Frame duration in microseconds freqoffset frequency offset linkstatus 0 non registered 1 registered lostframes logical frames lost manage show all fields of management group mgmtcrccou...

Страница 29: ... reboot show software summary Set parameters to factory default values If no parameter is specified configuration backup restore Use an FTP server to save and restore the subscriber configuration backup server file Save the subscriber configuration on a TFTP server server IP Address IP address of TFTP server file string Name of the binary file Must be located in the TFTP default directory restore ...

Страница 30: ...reboot yes Change to alternate software and reboot CPE Operator confirmation is required yes Perform operation without operator confirmation summary Display summary information CPE system summary Redline Communications Inc REM Active Software Image 2 2 5 Passive Software Image 2 2 4 4 3 12 tr069 Auto Configuration Servers Support Communication between CPE and Auto Configuration Servers ACS Table 1...

Страница 31: ...ime division duplex Tx Power Up to 26 66 dBm Rx Sensitivity 3 dB better than MRCT Network Attributes Transparent bridge 802 1p 802 1Q VLAN port tagging 802 1Q TOS DSCP and L2 L3 address traffic classification Modulation QPSK 16 QAM 64 QAM Forward Error Correction Convolutional Turbo Coder Decoder Over the Air Encryption AES Network Connections 10 100 Ethernet RJ 45 System Configuration SNMP FTP Ne...

Страница 32: ...et session to the subscriber using the following settings Login admin Password admin Enter the loadImage command The subscriber will prompt you to enter the following information Server IP address enter address of FTP server File Name enter base station binary file name The subscriber performs FTP server authentication with user name target and password secret these settings cannot be altered The ...

Страница 33: ...User REM Outdoor Subscriber Manual 70 00121 01 00 Proprietary Redline Communications 2009 Page 33 of 34 October 20 2009 ...

Страница 34: ...70 00121 01 00 Proprietary Redline Communications 2009 Page 34 of 34 October 20 2009 302 Town Centre Suite 100 Markham Ontario Canada L3R 0E8 www redlinecommunications com ...

Отзывы: