Summary of Contents for F2003 Series

Page 1: ...anual The user manual is suitable for the following model Model Product Type F2003 GSM IP MODEM Xiamen Four Faith Communication Technology Co Ltd Add J1 J3 3rd Floor No 44 GuanRi Road SoftWare Park XiaMen China Zip Code 361008 Tel 86 592 6300326 6300325 6300324 Fax 86 592 5912735 http www fourfaith com ...

Page 2: ...nication Technology Co Ltd Page 2 of 22 Add J1 J3 3 rd Floor No 44 GuanRiRoad SoftWare Park XiaMen 361008 China http www fourfaith com Tel 86 592 6300326 6300325 6300324 Fax 86 592 5912735 Files Revised Record Date Version Remark Author ...

Page 3: ...y Co Ltd Without written permission all commercial use of the files from Four Faith are forbidden such as copy distribute reproduce the files etc but non commercial purpose downloaded or printed by individual all files shall be not revised and the copyright and other proprietorship notice shall be reserved are welcome Trademark Notice Four Faith 四信 are all registered trademarks of Xiamen Four Fait...

Page 4: ... Xiamen Four Faith Communication Technology Co Ltd Page 4 of 22 Add J1 J3 3 rd Floor No 44 GuanRiRoad SoftWare Park XiaMen 361008 China http www fourfaith com Tel 86 592 6300326 6300325 6300324 Fax 86 592 5912735 ...

Page 5: ...nd Benefits 6 1 3 Working Principle 7 1 4 Specifications 7 Chapter 2 Installation Introduction 10 2 1 General 10 2 2 Encasement List 10 2 3 Installation and Cable Connection 10 2 4 Power 12 2 5 Indicator Lights Introduction 13 Chapter 3 Configuration 14 3 1 Configuration Connection 14 3 2 Enter Configure State 14 3 3 Configuration 15 3 3 1 Serial Port Parameters 15 3 3 2 Workmode 16 3 3 3 HEX SMS ...

Page 6: ... basic configuration It has been widely used on M2M fields such as intelligent transportation smart grid industrial automation telemetry finance POS water supply environment protection post weather and so on 1 2 Features and Benefits Design for Industrial Application High powered industrial cellular module High powered industrial 16 32 bits CPU Support low consumption mode including sleep mode sch...

Page 7: ...terface High performance Support transparent SMS data transfer Send SMS to up to 5 mobile numbers at the same time Support server and client functions Support CSD function 1 3 Working Principle The principle chart of the IP MODEM is as following 1 4 Specifications Cellular Specification Item Content Cellular Module Industrial cellular module Standard and Band EGSM900 GSM1800MHz GSM850 900 1800 190...

Page 8: ... Parity none even odd space mark Baud rate 110 230400 bps Indicator Power ACT Online Antenna Standard SMA female interface 50 ohm lighting protection optional SIM UIM Standard 3V 1 8V user card interface 15KV ESD protection Power Standard 3 PIN power jack reverse voltage and overvoltage protection Power Input Item Content Standard Power DC 12V 0 5A Power Range DC 5 35V Consumption 250mA 12V Physic...

Page 9: ...hnology Co Ltd Page 9 of 22 Add J1 J3 3 rd Floor No 44 GuanRiRoad SoftWare Park XiaMen 361008 China http www fourfaith com Tel 86 592 6300326 6300325 6300324 Fax 86 592 5912735 Storage Temperature 40 85º C 40 185 Operating Humidity 95 Non condensing ...

Page 10: ...912735 Chapter 2 Installation Introduction 2 1 General The IP MODEM must be installed correctly to make it work properly Warning Forbid to install the IP MODEM when powered 2 2 Encasement List Name Quantity Remark IP MODEM host 1 Antenna 1 Power adapter 1 RS232 data cable 1 optional RS485 data cable 1 optional Manual CD 1 Certification card 1 Maintenance card 1 2 3 Installation and Cable Connectio...

Page 11: ...out at once Put SIM UIM card into the card sheath Pay attention to put the side which has metal point outside and insert card sheath back to the SIM UIM card outlet Warning Forbid to install SIM UIM card when powered Installation of antenna Screw the SMA male pin of the antenna to the female SMA outlet of the IP MODEM tightly Warning The antenna must be screwed tightly or the signal quality of ant...

Page 12: ...12735 The signal connection of the RS485 data cable is as follows 2 4 Power The power range of the IP MODEM is DC 5 35V Warning When we use other power we should make sure that the power can supply power above 4W We recommend user to use the standard DC 12V 0 5A power adaptor DB9F DB9F RS232 data cable 1 RXD 2 TXD 3 4 GND 5 6 7 8 9 1 2 RXD 3 TXD 4 5GND 6 7 8 9 DB9F RS485 data cable 1 2 3 4 5 A 6 7...

Page 13: ...om Tel 86 592 6300326 6300325 6300324 Fax 86 592 5912735 2 5 Indicator Lights Introduction The IP MODEM provides three indicator lights Power ACT Online Indicator Light State Introduction Power ON IP MODEM is powered on OFF IP MODEM is powered off ACT BLINK Data is communicating OFF No data Online ON IP MODEM has logged on network OFF IP MODEM hasn t logged on network ...

Page 14: ... 592 5912735 Chapter 3 Configuration 3 1 Configuration Connection Before configuration it s necessary to connect the IP MODEM with the configure PC by the shipped RS232 or RS232 485 conversion cable as following 3 2 Enter Configure State Run FfSmsIP MODEMConfig En exe configure tool as following Click Open button State column displays the following information Software is waiting IP MODEM enter co...

Page 15: ...ourfaith com Tel 86 592 6300326 6300325 6300324 Fax 86 592 5912735 Re power IP MODEM Configure tool will make it enter configure state and load its current settings IP MODEM has been in configure state It s ready for configuring its parameters 3 3 Configuration 3 3 1 Serial Port Parameters Baud rate The serial port communication speed AT Command AT IPR xxxx ...

Page 16: ...ode According to different applications IP MODEM can be configured to different work mode AT Command AT MODE xxx xxx workmode TRNS IP MODEM works as a common GSM MODEM SMSSER This workmode is called SMS server mode When IP MODEM receives SMS it will read SMS and send out the SMS content to serial port To send SMS the SMS content should be encapsulated as the following format head frame header fixe...

Page 17: ...0x6f 0x03 数据解析 0x02 header 0x0b Peer phone number length It is 11 bytes 0x31 0x38 Peer phone number 13912345678 0x00 0x05 SMS content length It is 5 bytes 0x68 0x65 0x6c 0x6c 0x6f SMS content hello 0x03 tail SMSCLI This mode is called SMS client mode When IP MODEM receive SMS it will read SMS and send out the SMS content to serial port To send SMS It s necessary to configure Peer Phone refer 3 2 2...

Page 18: ...only when the workmode is SMSCLI It can be configured at most five peer phone numbers They are divided by comma AT Command AT PHON xxx xxx peer phone number 3 3 5 SMS Center SMS Center number of your ISP AT Command AT SMSC xxx xxx SMS Center number 3 3 6 Debug Level Debug level is used to control debug information the default value is 1 0 No debug information output 1 Simple prompt information 2 D...

Page 19: ...4 Fax 86 592 5912735 3 3 7 Retry Times The maximum retry times if send SMS fail AT Command AT RETRY xxx xxx Retry times value 3 3 8 Bytes Interval The time interval used to determine whether the serial data frame transmission has completed IP MODEM will send the serial data to peer phone when two bytes transmit time interval larger than this item value AT Command AT BYTEINT xxx xxx bytes interval ...

Page 20: ...300326 6300325 6300324 Fax 86 592 5912735 Appendix The following steps describe how to make IP MODEM enter configure state with the Windows XP Hyper Terminal 1 Press Start Programs Accessories Communications Hyper Terminal 2 Input connection name choose OK 3 Choose the correct COM port which connect to IP MODEM choose OK 4 Configure the serial port parameters as following choose OK ...

Page 21: ...oftWare Park XiaMen 361008 China http www fourfaith com Tel 86 592 6300326 6300325 6300324 Fax 86 592 5912735 Bits per second 115200 Data bits 8 Parity None Stop bits 1 Flow control None 5 Complete Hyper Terminal operation It runs as following 6 Re power IP MODEM put mouse focus on the Hyper Terminal and press s key ...

Page 22: ...rd Floor No 44 GuanRiRoad SoftWare Park XiaMen 361008 China http www fourfaith com Tel 86 592 6300326 6300325 6300324 Fax 86 592 5912735 continuously until IP MODEM enter configure state as following 7 IP MODEM has entered configure state you can configure the parameters through AT command ...