T1/E1 port configuration task list
60
OnSite 2800 Series User Manual
5 • T1/E1 port configuration
Mode:
port e1t1 <slot> <port>
Configuring T1/E1 port-type
The T1/E1 Port can either work in T1 or in E1 (G.704) mode. This mode can be changed dynamically as long
as no encapsulation or encapsulation ‘hdlc’ is set. Be aware that changing the port-type also resets the framing
and linecode parameters to the default values of the new port-type. If port-type change is not allowed due to
current configuration, an error message will be issued.
Mode:
port e1t1 <slot> <port>
Configuring T1/E1 clock-mode
The T1/E1 Port can either work in clock-master or in clock-slave mode. This setting defines the clock depen-
dency of the internal data processing. In clock-master mode the internal data processing is running on an inde-
pendent clock source. In clock-slave mode the clock source for internal data processing is recovered from the
receive line interface. Be aware that always a port-pair of clock-master and clock-slave are connected together.
In the other case the data transmission will fail due to bit failures.
Mode:
port e1t1 <slot> <port>
Configuring T1/E1 line-code
Three different line codes can be selected on the T1/E1 port whereas only ‘ami’ is standardized for E1 and T1.
If the port is running in E1 mode, ‘hdb3’ is also configurable and in T1 mode ‘b8zs’. If a linecode will be
selected that is not standardized for the current port mode, an error message will be advised.
Mode:
port e1t1 <slot> <port>
Step
Command
Purpose
1
[
name
] (prt-e1t1)[
slot/port
]# [no]
shutdown
Enable/Disable the T1/E1 port.
Default:
shutdown
(which is disabled)
Step
Command
Purpose
1
[
name
] (prt-e1t1)[
slot/port
]# port-type
{e1 | t1}
Changes operation mode of the port.
Default:
e1
Step
Command
Purpose
1
[
name
] (prt-e1t1)[
slot/port
]# clock {mas-
ter | slave}
Configures the clock-mode of the port.
Default:
master
Step
Command
Purpose
1
[
name
] (prt-e1t1)[
slot/port
]# linecode
{ami | b8zs | hdb3}
Configures the line-code of the port.
Default for e1:
hdb3
Default for t1:
b8zs
Содержание OnSite 2800 Series
Страница 112: ...112 Chapter 9 LEDs status and monitoring Chapter contents Status LEDs 113...
Страница 124: ...124 Appendix C Cabling Chapter contents Introduction 125 Serial console 125 Ethernet 10Base T and 100Base T 126...
Страница 132: ...132 Appendix E OnSite 2800 Series factory configuration Chapter contents Introduction 133...
Страница 134: ...134 Appendix F Installation checklist Chapter contents Introduction 135...