background image

 

9

 

Follow the steps below to connect the CopperLink interfaces.

 

Note

 

The Model 2156 or 2157 units work in pairs. One of the units 

must be a Model 2156/L (local) or 2157/L, and the other unit 
must be a Model 2156/R (remote) or 2157/R.

 

   1. To function properly, the two Ethernet Extenders must be connected 

together using twisted-pair, unconditioned, dry, metal wire, between 
19 (0.9mm) and 26 AWG (0.4mm). Leased circuits that run through 
signal equalization equipment are not acceptable.

   2. The Models 2156 and 2157 are equipped with an RJ-11 interface. 

The CopperLink interfaces are a two-wire interface. Observe the sig-
nal/pin relationships on the CopperLink interface jack.

The RJ-11 connector on the CopperLink Ethernet Extender’s twisted pair 
interface is polarity insensitive and is wired for a two-wire interface. The 
signal/pin relationship is shown in Figure 3.

 

Figure 3. 

 

CopperLink Ethernet Extender (RJ-11) twisted pair line interface.

 

3.2  LINE INTERFACE—CONNECTING THE 10/100BASE-T 

ETHERNET INTERFACE

 

The shielded RJ-45 port labeled 

 

Ethernet

 

 is the 10/100Base-T interface. 

This port is designed to connect directly to a 10/100Base-T network. 
Figure 4 shows the signal/pin relationships on this interface. You may 
connect this port to another Ethernet device via a Type 4 or Type 5 cable 
that is up to 328 ft (100 m) long.

Содержание 2156

Страница 1: ...USER MANUAL MODELS 2156 2157 CopperLink Ethernet Extenders SALES OFFICE 301 975 1000 TECHNICAL SUPPORT 301 975 1007 Part 07M2156_2157 Doc 032131U Rev A Revised 2 4 03 An ISO 9001Certified Company...

Страница 2: ...11 3 4 Power Input Connector 11 External AC universal power supply 11 External 48 VDC power supply 12 3 5 Console Port 13 4 0 Operation 14 4 1 Front Panel LED Status Monitors 14 A Specifications 15 A...

Страница 3: ...r 2157 generate and use radio frequency energy and if not installed and used properly that is in strict accordance with the manufacturer s instructions may cause interference to radio and televi sion...

Страница 4: ...Order Code s SOC 9 0F REN No 0 2 2 Your telephone company may make changes to its facilities equip ment operations or procedures that could affect the proper func tioning of your equipment The telepho...

Страница 5: ...not imply that Industry Canada approved the equipment 1 5 SERVICE All warranty and non warranty repairs must be returned freight prepaid and insured to Patton Electronics All returns must have a Retur...

Страница 6: ...ines see Appendix A on page 15 Transparent operation to higher level protocols such as TCP IP DEC net NETBIOS IPX etc Compatible with 802 1Q VLAN LED indicators for Power Ethernet Link 100Base T Opera...

Страница 7: ...7 Figure 1 Typical application The 2157 L and 2157 R work together to create a transparent extension between two peered Ethernet LANs Figure 1 shows a typical point to point application...

Страница 8: ...face on page 9 Connect the power plug refer to section 3 3 Connecting Power on page 11 Figure 2 CopperLink Ethernet Extender rear panel 3 1 CONNECTING THE TWISTED PAIR LINE INTERFACE The Models 2156 a...

Страница 9: ...erfaces are a two wire interface Observe the sig nal pin relationships on the CopperLink interface jack The RJ 11 connector on the CopperLink Ethernet Extender s twisted pair interface is polarity ins...

Страница 10: ...engage the crossover function so you won t have to use a crossover cable Figure 5 MDI X switch positions Note If you have difficulty achieving a working connection between the CopperLink Ethernet Ext...

Страница 11: ...TOR The CopperLink Ethernet Extender comes with an AC or DC power supply The supplies connection to the CopperLink Ethernet Extender is a 2 5 mm barrel receptacle with the center conductor positive se...

Страница 12: ...y that incorporates a disconnect device must be used and positioned within easy reach of the operator s position Caution Connect the equipment to a 5 VDC source that is electri cally isolated from the...

Страница 13: ...13 3 5 CONSOLE PORT The Console Port is only intended for use by Patton Electronics Technical Support technicians...

Страница 14: ...LED Table 1 describes the LED functions Figure 9 CopperLink Ethernet Extender standalone unit front panel Table 1 Front panel LED description LED Description Power When lit indicates the unit is power...

Страница 15: ...ernal UI or 48 VDC power supply options Standard 1 year warranty A 2 WAN CHARACTERISTICS 2 3 Mbps Model 2156 or 4 6 Mbps speed Model 2157 RJ 11 connector Uses two wire unconditioned twisted pair A 3 E...

Страница 16: ...6 9 5 6 9 0 5 9 9 6 36 2312 2 3 3 8 3 1 5 0 4 0 6 6 5 3 8 6 5 6 9 1 Table 3 Model 2157 Extension Distances DSL line rate No Noise 26g 0 4 mm 24g 0 5 mm 22g 0 6 mm 20g 0 8 mm 19g 0 9 mm N kbps miles km...

Страница 17: ...k Ethernet Extender requires 5VDC 5 DC power 1 0A minimum Center pin is 5V The barrel type plug has a 2 5 5 5 10mm I D O D shaft length dimensions CopperLink Ethernet Extender s rated voltage 5 0 VDC...

Страница 18: ...Link Ethernet Extender Line RJ 11 Local 2157 R CopperLink Ethernet Extender Line RJ 11 Remote 2157 2PK CopperLink Ethernet Extender Kit includes one local L and one remote R Model 2157 2156 and 2157 U...

Страница 19: ...S 2156 AND 2157 SERIES INTERFACE PIN ASSIGNMENT C 1 10 100BASE T INTERFACE RJ 45 Pin 1 TX Pin 2 TX Pin 3 RX Pin 6 RX Pins 4 5 7 8 no connection C 2 COPPERLINK INTERFACE RJ 11 Pin 2 RING Pin 3 TIP Pins...

Страница 20: ...____________________________________________ ________________________________________________________ ________________________________________________________ _________________________________________...

Отзывы: