A.5  LED INDICATORS

 

• Eight LED indicators

• Power

• WAN Link, Transmit, and Receive

• Ethernet Link, 100M, Transmit, and Receive

 

A.6  POWER AND POWER SUPPLY SPECIFICATIONS

 

• Either AC or DC options are available

• Connection to the CopperLink Ethernet Extender re5VDC 

±5% DC power (1.0A minimum). Center pin is +5V. The barrel type 
plug has a 2.5/5.5/10mm I.D./O.D./shaft length dimensions

• CopperLink Ethernet Extender’s rated voltage: 5.0 VDC

• CopperLink Ethernet Extender’s rated current:  1A DC

 

A.7  ENVIRONMENTAL

 

• Temperature: 32–122°F (0–50°C)

• Relative Humidity: 5–90%, non-condensing

• Altitude: 0–15,000 ft (0–4,572 m)

 

A.8  DIMENSIONS

 

1.5H x 4.2W x 5.8D in. (3.8H x 10.6W x 14.8D cm)

Содержание 2156

Страница 1: ...USER MANUAL MODELS 2156 2157 CopperLink Ethernet Extenders SALES OFFICE 301 975 1000 TECHNICAL SUPPORT 301 975 1007 Part 07M2156_2157 Doc 032131U Rev A Revised 2 4 03 An ISO 9001Certified Company...

Страница 2: ...11 3 4 Power Input Connector 11 External AC universal power supply 11 External 48 VDC power supply 12 3 5 Console Port 13 4 0 Operation 14 4 1 Front Panel LED Status Monitors 14 A Specifications 15 A...

Страница 3: ...r 2157 generate and use radio frequency energy and if not installed and used properly that is in strict accordance with the manufacturer s instructions may cause interference to radio and televi sion...

Страница 4: ...Order Code s SOC 9 0F REN No 0 2 2 Your telephone company may make changes to its facilities equip ment operations or procedures that could affect the proper func tioning of your equipment The telepho...

Страница 5: ...not imply that Industry Canada approved the equipment 1 5 SERVICE All warranty and non warranty repairs must be returned freight prepaid and insured to Patton Electronics All returns must have a Retur...

Страница 6: ...ines see Appendix A on page 15 Transparent operation to higher level protocols such as TCP IP DEC net NETBIOS IPX etc Compatible with 802 1Q VLAN LED indicators for Power Ethernet Link 100Base T Opera...

Страница 7: ...7 Figure 1 Typical application The 2157 L and 2157 R work together to create a transparent extension between two peered Ethernet LANs Figure 1 shows a typical point to point application...

Страница 8: ...face on page 9 Connect the power plug refer to section 3 3 Connecting Power on page 11 Figure 2 CopperLink Ethernet Extender rear panel 3 1 CONNECTING THE TWISTED PAIR LINE INTERFACE The Models 2156 a...

Страница 9: ...erfaces are a two wire interface Observe the sig nal pin relationships on the CopperLink interface jack The RJ 11 connector on the CopperLink Ethernet Extender s twisted pair interface is polarity ins...

Страница 10: ...engage the crossover function so you won t have to use a crossover cable Figure 5 MDI X switch positions Note If you have difficulty achieving a working connection between the CopperLink Ethernet Ext...

Страница 11: ...TOR The CopperLink Ethernet Extender comes with an AC or DC power supply The supplies connection to the CopperLink Ethernet Extender is a 2 5 mm barrel receptacle with the center conductor positive se...

Страница 12: ...y that incorporates a disconnect device must be used and positioned within easy reach of the operator s position Caution Connect the equipment to a 5 VDC source that is electri cally isolated from the...

Страница 13: ...13 3 5 CONSOLE PORT The Console Port is only intended for use by Patton Electronics Technical Support technicians...

Страница 14: ...LED Table 1 describes the LED functions Figure 9 CopperLink Ethernet Extender standalone unit front panel Table 1 Front panel LED description LED Description Power When lit indicates the unit is power...

Страница 15: ...ernal UI or 48 VDC power supply options Standard 1 year warranty A 2 WAN CHARACTERISTICS 2 3 Mbps Model 2156 or 4 6 Mbps speed Model 2157 RJ 11 connector Uses two wire unconditioned twisted pair A 3 E...

Страница 16: ...6 9 5 6 9 0 5 9 9 6 36 2312 2 3 3 8 3 1 5 0 4 0 6 6 5 3 8 6 5 6 9 1 Table 3 Model 2157 Extension Distances DSL line rate No Noise 26g 0 4 mm 24g 0 5 mm 22g 0 6 mm 20g 0 8 mm 19g 0 9 mm N kbps miles km...

Страница 17: ...k Ethernet Extender requires 5VDC 5 DC power 1 0A minimum Center pin is 5V The barrel type plug has a 2 5 5 5 10mm I D O D shaft length dimensions CopperLink Ethernet Extender s rated voltage 5 0 VDC...

Страница 18: ...Link Ethernet Extender Line RJ 11 Local 2157 R CopperLink Ethernet Extender Line RJ 11 Remote 2157 2PK CopperLink Ethernet Extender Kit includes one local L and one remote R Model 2157 2156 and 2157 U...

Страница 19: ...S 2156 AND 2157 SERIES INTERFACE PIN ASSIGNMENT C 1 10 100BASE T INTERFACE RJ 45 Pin 1 TX Pin 2 TX Pin 3 RX Pin 6 RX Pins 4 5 7 8 no connection C 2 COPPERLINK INTERFACE RJ 11 Pin 2 RING Pin 3 TIP Pins...

Страница 20: ...____________________________________________ ________________________________________________________ ________________________________________________________ _________________________________________...

Отзывы: