1.3  FCC PART 68

 

   1. You are required to request service from the telephone company before 

you connect the Model 2156 or 2157 to a network. When you request 
service, you must provide the telephone company with the following 
data.

The required Universal Service Order code (USOC) jack: RJ-11C

The make, model number, Ringer Equivalence Number (REN), 

and FCC Registration number of the Model 2156 or 2157.

The REN helps you determine the number of devices you can con-
nect to your telephone line and still have all of those devices ring 
when your number is called. In most, but not all, areas, the sum of 
the RENs of all devices should not exceed five (5.0). To be certain of 
the number of devices you can connect to your line, you should call 
your local telephone company to determine the maximum REN.

The Facility Interface Code: 

 

02LS2

 

The Service Order Code(s) (SOC): 

 

9.0F

 

REN No.: 

 

0.2

 

   2. Your telephone company may make changes to its facilities, equip-

ment, operations, or procedures that could affect the proper func-
tioning of your equipment. The telephone company will notify in 
advance of such changes to give you an opportunity to maintain 
uninterrupted telephone service.

   3. If your Model 2156 or 2157 causes harm to the telephone network, 

the telephone company may temporarily discontinue your service. If 
possible, they will notify you in advance, but if advance notice is not 
practical, you will be notified as soon as possible and will be 
informed of your right to file a complaint with the FCC.

   4. If you experience trouble with the Model 2156 or 2157, contact Pat-

ton Electronics Company for service or repairs. Repairs should be 
performed only by Patton Electronics Co.

   5. You are required to notify the telephone company when you discon-

nect the Model 2156 or 2157 from the network.

 

Caution

 

The Models 2156 and 2157 are not intended to be con-
nected to the public telephone network.

Содержание 2156

Страница 1: ...USER MANUAL MODELS 2156 2157 CopperLink Ethernet Extenders SALES OFFICE 301 975 1000 TECHNICAL SUPPORT 301 975 1007 Part 07M2156_2157 Doc 032131U Rev A Revised 2 4 03 An ISO 9001Certified Company...

Страница 2: ...11 3 4 Power Input Connector 11 External AC universal power supply 11 External 48 VDC power supply 12 3 5 Console Port 13 4 0 Operation 14 4 1 Front Panel LED Status Monitors 14 A Specifications 15 A...

Страница 3: ...r 2157 generate and use radio frequency energy and if not installed and used properly that is in strict accordance with the manufacturer s instructions may cause interference to radio and televi sion...

Страница 4: ...Order Code s SOC 9 0F REN No 0 2 2 Your telephone company may make changes to its facilities equip ment operations or procedures that could affect the proper func tioning of your equipment The telepho...

Страница 5: ...not imply that Industry Canada approved the equipment 1 5 SERVICE All warranty and non warranty repairs must be returned freight prepaid and insured to Patton Electronics All returns must have a Retur...

Страница 6: ...ines see Appendix A on page 15 Transparent operation to higher level protocols such as TCP IP DEC net NETBIOS IPX etc Compatible with 802 1Q VLAN LED indicators for Power Ethernet Link 100Base T Opera...

Страница 7: ...7 Figure 1 Typical application The 2157 L and 2157 R work together to create a transparent extension between two peered Ethernet LANs Figure 1 shows a typical point to point application...

Страница 8: ...face on page 9 Connect the power plug refer to section 3 3 Connecting Power on page 11 Figure 2 CopperLink Ethernet Extender rear panel 3 1 CONNECTING THE TWISTED PAIR LINE INTERFACE The Models 2156 a...

Страница 9: ...erfaces are a two wire interface Observe the sig nal pin relationships on the CopperLink interface jack The RJ 11 connector on the CopperLink Ethernet Extender s twisted pair interface is polarity ins...

Страница 10: ...engage the crossover function so you won t have to use a crossover cable Figure 5 MDI X switch positions Note If you have difficulty achieving a working connection between the CopperLink Ethernet Ext...

Страница 11: ...TOR The CopperLink Ethernet Extender comes with an AC or DC power supply The supplies connection to the CopperLink Ethernet Extender is a 2 5 mm barrel receptacle with the center conductor positive se...

Страница 12: ...y that incorporates a disconnect device must be used and positioned within easy reach of the operator s position Caution Connect the equipment to a 5 VDC source that is electri cally isolated from the...

Страница 13: ...13 3 5 CONSOLE PORT The Console Port is only intended for use by Patton Electronics Technical Support technicians...

Страница 14: ...LED Table 1 describes the LED functions Figure 9 CopperLink Ethernet Extender standalone unit front panel Table 1 Front panel LED description LED Description Power When lit indicates the unit is power...

Страница 15: ...ernal UI or 48 VDC power supply options Standard 1 year warranty A 2 WAN CHARACTERISTICS 2 3 Mbps Model 2156 or 4 6 Mbps speed Model 2157 RJ 11 connector Uses two wire unconditioned twisted pair A 3 E...

Страница 16: ...6 9 5 6 9 0 5 9 9 6 36 2312 2 3 3 8 3 1 5 0 4 0 6 6 5 3 8 6 5 6 9 1 Table 3 Model 2157 Extension Distances DSL line rate No Noise 26g 0 4 mm 24g 0 5 mm 22g 0 6 mm 20g 0 8 mm 19g 0 9 mm N kbps miles km...

Страница 17: ...k Ethernet Extender requires 5VDC 5 DC power 1 0A minimum Center pin is 5V The barrel type plug has a 2 5 5 5 10mm I D O D shaft length dimensions CopperLink Ethernet Extender s rated voltage 5 0 VDC...

Страница 18: ...Link Ethernet Extender Line RJ 11 Local 2157 R CopperLink Ethernet Extender Line RJ 11 Remote 2157 2PK CopperLink Ethernet Extender Kit includes one local L and one remote R Model 2157 2156 and 2157 U...

Страница 19: ...S 2156 AND 2157 SERIES INTERFACE PIN ASSIGNMENT C 1 10 100BASE T INTERFACE RJ 45 Pin 1 TX Pin 2 TX Pin 3 RX Pin 6 RX Pins 4 5 7 8 no connection C 2 COPPERLINK INTERFACE RJ 11 Pin 2 RING Pin 3 TIP Pins...

Страница 20: ...____________________________________________ ________________________________________________________ ________________________________________________________ _________________________________________...

Отзывы: