- 71 -
PATON
StandardMIG
DC MMA/TIG/MIG/MAG
Connection to power line/po
wer panel (at 25ºC
):
WARNING! Consider wires in walls and other extensions
Electrode to be
used in MMA
mode
Set current
value for MMA
and TIG
Wire cross-
section diameter
at MIG/MAG
Cross-section of
each core of the
mains cable
, mm²
Maximum
cable length,
m
1 x 220V/230V
–
StandardMIG-160, StandardMIG-200, StandardMIG-250
Ø
2 mm
Max.
80А
Max.
Ø
0.6 mm
1.0
75
1.5
115
2.0
155
2.5
195
4.0
310
Ø
3 mm
Max.
120А
Max.
Ø
0.8 mm
1.5
75
2.0
105
2.5
130
4.0
205
6.0
310
Ø
4 mm
Max.
160А
Up to
Ø
1.0 mm
2.0
75
2.5
95
4.0
155
6.0
230
Ø
5 mm
Max.
200А
2.5
75
4.0
125
6.0
185
Ø
5 mm
Ø6
mm
fusible
Up to
250А
Up to
Ø
1.2 mm
2.5
60
4.0
100
6.0
150
3 x 380V/400V
–
StandardMIG-270, StandardMIG-350
Ø
3 mm
Max.1
20А
Max.
Ø
0.8 mm
1.5
135
2
175
2.5
220
4
350
6
525
Ø
4 mm
Max.
160А
Max.
Ø
1.0 mm
2
130
2.5
160
4
260
6
385
Ø
5 mm
Max.
220А
2.5
115
4
180
6
270
Ø
6 mm
fusible
Max. 27
0А
Max.
Ø
1.2 mm
2.5
85
4
135
6
205
Ø
6 mm
Up to
350А
Max.
Ø
1.4 mm
2.5
65
4
100
6
150
Содержание StandardMIG-160
Страница 1: ......
Страница 2: ......
Страница 100: ... 99 PATON StandardMIG DC MMA TIG MIG MAG PATON StandardMIG 270 400V 350 400V DC MMA TIG MIG MAG source circuit diagram ...