- 92 -
corner of the display on the front of the source. When the machine is first turned on, the
program is always No. 1 for each welding mode. All changes to the machine settings in a
given weld mode and the current program number are saved.
To switch to another program number and start setting again from the basic
parameters, it is necessary to press button
3
and if the function selection menu is locked,
then the display will show the current program number, which can be changed up or down
using buttons
1
. If the function selection menu is not locked, for example: the user has just
before that changed the additional function parameters described in paragraph 6.1, it is
necessary to lock the function selection menu by holding down button
3
for more than 3.5
seconds, in the same way as when unlocking. The indicator will show the closing locks.
After this operation is over, the menu will be locked and now you can try to change the
program number again by using button
3
. In this case, all the parameters of the previous
program will be saved and you can always return to it again.
7. GENERAL LIST AND SEQUENCE OF FUNCTIONS
MMA welding mode
0)
Main displayable parameter CURRENT= 90А (default
)
a) 8 ... 160
А
(unit increment 1
А
) for StandardMIG-160
b) 10 ... 200
А
(unit increment 1
А
) for StandardMIG-200
c) 12 ... 250
А
(unit increment 1
А
) for StandardMIG-250
d) 12 ... 270
А
(unit increment 1
А
) for StandardMIG-270
e) 14 ... 350
А
(unit increment 1
А
) for StandardMIG-350
1) Hot Start power = 40% (default)
a) 0[OFF] ... 100% (unit increment 5%)
2) Hot Start time = 0.3 sec (default)
a) 0.1 ... 1.0 sec (unit increment 0.1 sec)
3) Arc Force power = 40% (default)
a) 0[OFF] ... 100% (unit increment 5%)
4) Arc Force triggering level = 12V (default)
a) 9 ... 18V (unit increment 1V)
5) Voltage response slope = 1.4V/A (default)
a) 0.2 ... 1.8V/A (unit increment 0.4V/A)
6) Short arc welding = OFF (default)
a) ON
–
enabled
b) OFF
–
disabled
7) Voltage reduction unit = OFF (default)
a) ON
–
enabled
b) OFF
–
disabled
8) Current pulsation power = OFF (default)
a) 0[OFF] ... 80% (unit increment 5%)
9) Current pulsation frequency = 5.0 Hz (default)
a) 0.2
... 500 Hz (dynamic unit increment 0.1 Hz … 1 Hz)