5) [t.dn] wire feed speed decay time = 0.1 sec (by default)
a) 0.1 ... 5.0 sec (step change 0.1 sec)
5. SERVICE AND MAINTENANCE
Warning!
Before opening the unit, turn it off and remove the mains plug. Allow the
internal circuits of the unit to discharge (approximately 1 minute) and only then
perform the rest of the operation. When leaving, put a sign prohibiting switching on.
In order to keep the wire feeder operable for many years, a few rules must be
observed:
-
Perform safety inspections at specified intervals (see Section "Safety
Instructions");
-
If intensively used, we recommend blowing out the unit with dry compressed
air once every 6 months.
Warning!
Blowing from a too-short distance can damage
the electronic components.
6. GENERATOR OPERATION MODE
Wire feeder consumes extremely low power, usually not exceeding 100W, so the
main condition is that the output voltage of the generator must not exceed the
permissible limits of 180-260V.
7. STORAGE REGULATIONS
Preserved and packed wire feeder should be kept in storage conditions 4 of State
Standard 15150-69 for 5 years.
Unpacked wire feeder should be stored in a dry closed room at air temperature not
lower than +5 °C. There should be no vapors of acids and other active substances
on
the premises.
8. TRANSPORTATION
Packed wire feeder can be transported by all means ensuring its safety in compliance
with the rules of transportation established for the relevant type of transport.
9. SCOPE OF DELIVERY
1.
Wire feeder unit
–
1 pc;
2.
Pneumatic quick connector
–
1 pc;
3.
Operation manual
–
1 pc.
4.
PATON branded corrugated box
–
1 pc;
For Feeder-15-2 model:
-
ABICOR BINZEL semi-automatic torch
–
1 pc;
-
Rollers for solid wire 0,6-0,8; 1,0-1,2
–