PATON
Feeder
DC MIG/MAG
- 10 -
3.2.1 TORCH BUTTON FUNCTION - 4T and
_4Т
а)
World standard button mode -
4Т
б)
Alternative button mode -
_4Т
It is used when welding long welds. The function is as follows: when you press the
button on the torch, the control signal goes to the control unit, the function of pre-
purging the welding zone with gas (gas valve opens) is executed; after the first
release of the button, the signal to turn on the source and the wire feeder motor is
released. From that moment, the welding process starts. At the same time, the
function of gradual entering the welding mode in time [t.uP], as well as additional
functions (for example, the last generation of PATON digital sources have a pulse
mode) are executed. All this is according to the welding process cycle shown in the
cyclogram of cl. 3.2.
4. SWITCHING TO THE DESIRED FUNCTION
If the tamper protection system for the function menu is installed, no change occurs
on the display when button
6
is pressed, i.e. this button is locked. To unlock it, it is
necessary to hold it pressed for more than 3.5 seconds. When unlocked, horizontal
bars will appear on the display indicating that the function menu is unlocked. After
successful unlocking, pressing button
6
will display the graphic name of the current
function on the numeric display and, as long as it is held down, it can be viewed.
After releasing the button, the current value of this function is displayed, which can
be changed up or down using the buttons
3
. By quickly pressing and releasing button
5
, you can switch to the next function in a circle.
4.1 GENERAL LIST AND SEQUENCE OF FUNCTIONS
0) [-1-] The main displayed parameter FEED RATE = 7.0 m/min (default)
a) 2.0 ... 16.0 m/min (step change 0.1 m/min)
1) [But] torch button mode = [2T] (default)
а) [2t] –
2Т torch button mode
б) [4t] –
standard button mode on 4T torch
в) [_4t] –
alternative button mode on 4T burner
2) [t.Pr] time of pre-purging time with safety gas = 0.1 sec (by default)
а) 0
.1 ... 25.0 sec (step change 0.1 sec)
3) [t.P0] time of post-purging time with safety gas = 1.5 sec (by default)
a) 0.1 ... 25.0 sec (step change 0.1 sec)
4) [t.uP] wire feeder ramp up time = 0.1 sec (by default)
a) 0.1 ... 5.0 sec (step change 0.1 sec)