piece

 

 

 

TECHNICAL PARAMETERS

 

 

 

 

 

 

 

 

 

 

 

 

   

   

 

 

 

 

 

 

 

 

   

 

 

PARAMETERS

 

 

EuroMIG

 

   

 

 

Rated supply mains voltage 50Hz, V

 

220

 

 

 

   

 

 

230

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rated input current from mains, А

 

 

 

17…20

 

   

 

 

Rated welding current, A

 

150

 

 

 

   

 

 

Maximum operating current, A

 

200

 

 

 

   

 

 

Duty cycle (DC)

 

 

80%/at 150А

 

   

 

 

 

100%/at 134A

 

 

 

 

 

 

 

 

 

 

 

Voltage variation limits of mains voltage, V

 

 

160 

 260

 

   

 

 

Rated supply mains voltage 50Hz, V

 

 

 

8

150

 

   

 

 

Rated input current from mains, А

 

 

 

12

23

 

   

 

 

Wire feed speed control limits, m/min

 

 

1,5 

 10,0

 

   

 

 

Stick electrode diameter, mm

 

 

2T, 4T, SPOT

 

   

 

 

Solid welding wire diameter, mm

 

 

 

0,6 

 1,0

 

   

 

 

Wire feeder mechanism

 

 

 

2 roller

 

   

 

 

Maximum weight of the coil, kg

 

5

 

 

 

   

 

 

 

 

MMA: 0,2...500Гц;

 

   

 

 

Pulsed welding modes

 

 

TIG: 0,2...500Гц;

 

   

 

 

 

 

MIG/MAG: 5...500Гц

 

   

 

 

Stick electrode diameter, mm

 

 

 

1,6 

 4,0

 

   

 

 

Hot-Start in MMA mode

 

 

Adjustable

 

   

 

 

Arc-Force in MMA mode

 

 

Adjustable

 

   

 

 

Anti-Stick in MMA mode

 

 

Automatic

 

   

 

 

No-load voltage reduction unit in MMA mode

 

 

 

on/off

 

   

 

 

No-load voltage in MMA mode, V

 

12/75

 

 

 

   

 

 

Arc ignition voltage, V

 

110

 

 

 

   

 

 

Rated input power, kVA

 

 

 

3,8 … 4,4

 

   

 

 

Maximum input power, kVA

 

5,5

 

 

 

   

 

 

Efficiency, %

 

90

 

 

 

   

 

 

Cooling

 

 

 

Adaptive

 

   

 

 

Operating temperature range

 

 

–25 … +45ºС

 

   

 

 

Dimensions, mm (length, width, height)

 

 

390 х 194 х 295

 

   

 

 

Weight without coil and accessories, kg

 

9.2

 

 

 

   

 

 

Protection class*

 

 

 

IP21

 

   

 

 

 

SELECTING AND SETTING THE FUNCTIONS OF THE MACHINE

 

 

If you do not press the buttons on the front panel, the unit displays the value of the main parameter of the current welding mode on the 
digital indicator on the left:

 

 

1) in the MMA mode 

 welding current;

 

 

-5 -

 

PATON 

EuroMIG

 DC MMA/TIG/MIG/MAG

 

Содержание EuroMIG

Страница 1: ......

Страница 2: ...orn goggles must be equipped with goggles with a DIN 9 10 filter Unauthorized persons in the operating area of the device must protect their eyes with special goggles or use non flammable radiation ab...

Страница 3: ...pneumatic connector 1 Buttons to adjust the selected parameter to decrease and increase default for MMA welding current for TIG welding current MIG MAG welding voltage 2 Digital display 3 Button for s...

Страница 4: ...der shall be connected START UP The welding unit is designed exclusively for MMA welding tungsten arc inert gas TIG welding as well as metal arc inert gas welding metal active gas welding MIG MAG Othe...

Страница 5: ...ains after completion of welding Machine connection diagram for welding with stick electrodes MMA electrode holder ground terminal piece Recommended length of power welding cables during welding Maxim...

Страница 6: ...ht of the coil kg 5 MMA 0 2 500 Pulsed welding modes TIG 0 2 500 MIG MAG 5 500 Stick electrode diameter mm 1 6 4 0 Hot Start in MMA mode Adjustable Arc Force in MMA mode Adjustable Anti Stick in MMA m...

Страница 7: ...e the display is showing the current function its value can be changed up or down using buttons 1 Alternatively by quickly pressing and releasing button 3 you can switch to the next function in a circ...

Страница 8: ...on of these pulses 50 by default a 20 80 change step 5 MIG MAG welding mode On the left source display 0 Main displayable parameter VOLTAGE 19 0 V default a 12 0 23 0V unit increment 0 1V 1 Ind Induct...

Страница 9: ...d motor on off ON default a ON enabled b OFF disabled 4 t Pr pre purge time with safety gas 0 1 sec default a 0 1 25 0 sec unit increment 0 1 sec 5 t P0 post purge time with safety gas 0 1 sec default...

Страница 10: ...nnectors with traces of corrosion which caused a malfunction out of order due to exposure to its power and electronic elements of abundant moisture failed due to the accumulation of conductive dust in...

Страница 11: ...__________________________________________________________________________________ ___________________________________________________________________________________________________________________ _...

Страница 12: ...________________________________________________ ___ Date of receipt for repair _________________ _____ 20____ _____________________________ signature Symptoms of non operability _____________________...