32
Lever
Terminal Block Connector
Body Unit
2 3
5 6
7
8
9
1
4
1
2 Orange
3 Green
4
Blue
5 White
6 Gray
7 Yellow
8 Gray
9 Black
Red
LED-R
LED-Y
LED-G
LED-B
LED-C
Buzzer
Power Supply Wire (Common)
Flashing Common
Power Supply Wire (Signal-line Side)
Terminal Block Array
WT KT
■
Recommended Lead-wire Specifications
UL1007 / UL1430
Wire Type
0.14
〜
1.5mm
2
Wire Gauge (Solid Wire)
AWG30
〜
14
Wire Gauge (Frayed Wire)
Point
Terminal Block Wiring Method
WT KT
●
The minus driver blade should be at about 2mm by 0.5mm in
size.
●
Do not forcibly push the lever more than necessary with the
driver. Failure to comply may damage the unit.
●
Strip 9 to 10mm of wire insulation from the wire to insert it in
the Terminal Block.
●
When removing the lead wire, do not pull to remove, be sure
to operate the lever to release the lock.
Remove the connector from the body unit before wiring.
Attach the terminal block connector to the body unit after wiring.
※
The terminal block connector is attached to the body unit at all times after factory shipment. Refer to pg.49 for “Unit
Detachment Method” for removal, wiring and attachment.
●
Temperature rating should be above 75
0
C, and the conductor
material should be of copper wire.
1
A minus driver etc. is used to pry the
lever slot of the Terminal Block open,
by pushing straight onto the lever slot.
2
The stripped side of the lead
wire is inserted in the slot.
3
The driver is removed to
release the lever. (Check to
make sure
the lead wire has been locked
in place.)