Patlite LR4 Скачать руководство пользователя страница 1

1

Thank you very much for purchasing our PATLITE product.

Request the installation and wiring be performed by a 

professional contractor if construction work is involved.

Prior to installation, read this manual thoroughly before 

using this product to ensure correct use.

After reviewing this manual, if there are any questions 

regarding this product, please contact the nearest 

PATLITE office listed on the back cover of this manual.

Notice to Customer

Read this manual carefully prior to  installation.

Be sure to return this manual to the customer.

Notice to Contractor

2

3

7

19

33

34

35

50

51

23

Page

1

2

3

4

5

6

7

8

9

10

Specifications

Complete Operation Manual

TYPE

L R 4   /   L R 5   /

L R 6   /   L R 7

B95100502_02

55

11

Replacement Parts

57

12

Optional Parts

Signal Tower

Installation

Operation

Maintenance

Safety Precautions

Model Number
Configuration

Part Names and
Outer Appearance

Installation

Wiring

Buzzer Pattern Set-up

How to use 
the Folding Bracket

Unit Detachment 
Method

Troubleshooting

ghv Vertriebs-GmbH

 | Am Schammacher Feld 47 | 85567 Grafing | T 49 80 92 81 89 0 | [email protected] |

 www.ghv.de

Содержание LR4

Страница 1: ...stomer Read this manual carefully prior to installation Be sure to return this manual to the customer Notice to Contractor 2 3 7 19 33 34 35 50 51 23 Page 1 2 3 4 5 6 7 8 9 10 Specifications Complete...

Страница 2: ...packing from the equipment which is attached to this product be careful not to snag the product Failure to comply may result in damage to the product To ensure proper safety while using the signal to...

Страница 3: ...Silver 4 LR4 502PJBU RYGBC 40 LED 5 Tiers 24V DC Pole Mount with Circular Bracket Cable With Flashing Buzzer Silver From top Red Amber Green Blue White Color Globe LR4 302WJBW RYGZ 40 LED 3 Tiers 24V...

Страница 4: ...Black 4 LR5 502PJBW RYGBC 50 LED 5 Tiers 24V DC Pole Mount with Circular Bracket Cable With Flashing Buzzer Off white From top Red Amber Green Blue White Color Globe LR5 302WJBW RYG 50 LED 3 Tiers 24V...

Страница 5: ...ole Mount with Circular Bracket Cable With Flashing Buzzer Silver From top Red Amber Green Blue White Color Globe LR6 302WJBW RYGZ 60 LED 3 Tiers 24V DC Direct Mount Cable With Flashing Buzzer Off whi...

Страница 6: ...with knock outs Terminal Body Unit 1 Unit Model Body Unit 7 LR W Off white U Silver 3 K Black 3 LR7 502WJBW RYGBC 50 LED 5 Tiers 24V DC Direct Mount Cable With Flashing Buzzer Off white From top Red...

Страница 7: ...B N 02 M2 LED Tiers Model Flashing Buzzer Rated Voltage QJ WJ PJ LJ Mounting Wiring LED Tiers Model Flashing Buzzer Rated Voltage Mounting Wiring LR4 Tier 1 Tiers Drawing is Tiers 5 5 Tier 1 Tiers Dra...

Страница 8: ...uzzer Rated Voltage Mounting Wiring LED Tiers Model Flashing Buzzer Rated Voltage Mounting Wiring Tier 1 Tiers Drawing is Tiers 5 5 Tier 1 Tiers Drawing is Tiers 5 5 WC B N 02 M2 02 Tiers 3 ghv Vertri...

Страница 9: ...del Flashing Buzzer Rated Voltage Mounting Wiring Model Flashing Buzzer Rated Voltage Mounting Wiring LR4 N PJ M2 02 N WJ LR7 02 02 M2 QJ WJ LJ LR6 N PJ M2 02 N WT LR7 02 N LR5 WC 02 M2 02 02 M2 02 KT...

Страница 10: ...bber Material Cable 7 PC PC Globe PC PC PC PVC Accessory Hexagon Nut with Flange M3 3 pcs LR4 5 WJ Hexagon Nut with Flange M4 3 pcs LR6 7 WJ LR 99 LR 1 139 LR 2 179 LR 3 219 LR 4 259 LR 5 299 LR WJB L...

Страница 11: ...SUM PVC PC 01 02 LR LJB LR LJN 40 LR4 40 LR5 50 LR6 60 21 7 90 53 5 285 21 7 LR4 40 LR5 50 LR6 60 40 19 20 55 80 3 90 LR 99 LR 1 139 LR 2 179 LR 3 219 LR 4 259 LR 5 299 285 20 LR 1 173 5 LR 2 213 5 L...

Страница 12: ...t M22 SUM PVC PC M2 Unit mm LR M2LJBW LR M2LJNW 40 21 7 53 5 285 21 7 40 19 20 55 80 3 90 285 20 15 15 90 LR4 40 LR6 60 LR4 40 LR6 60 LR 1M2 243 5 LR 2M2 283 5 LR 3M2 323 5 LR 4M2 363 5 LR 5M2 403 5 L...

Страница 13: ...Accessory Cross Recessed Pan Head Screw M4x20 3pcs Hexagon Nut with Flange M4 3pcs LR4 5 6 PJ Cable UL2464 7 5 Signal Wire Power Supply Wire AWG24 Cable Length Off white 1000 Silver 3000 LR4 LR6 6 6...

Страница 14: ...M2PJBW LR M2PJNW Cross Recessed Pan Head Screw M4x20 Hexagon Nut with Flange M4 3pcs 3pcs Accessory LR4 6 PJ 35 6 40 40 21 7 290 21 7 290 90 60 53 5 19 15 15 35 6 90 60 LR 1M2 243 5 LR 2M2 283 5 LR 3M...

Страница 15: ...253 5 LR 402 293 5 LR 502 333 5 No Name 1 Buzzer Unit 2 Head Cover 3 LED Unit 4 Body 5 Pole Bracket 6 Pole 7 Folding Bracket Material 8 Waterproof Packing 9 Cable Globe PC PC PC AL CR PC PC PC PVC Acc...

Страница 16: ...ket 6 Waterproof Packing t 1 M30 Nut Material PC Silicone Rubber PC PC Globe PC PC 02 Unit mm LR6 02WCNW 40 60 19 LR6 02 126 LR6 302 246 25 10 52 M30 1 5 1 2 NPT Internal Threads Maximum Board Thickne...

Страница 17: ...e M3 Hexagon Nut with Flange M4 3 pcs Accessory LR5 WT Hexagon Nut with Flange M3 Maximum Board Thickness 7 Direct Mount with Terminal Block Unit mm WT No Name 1 Buzzer Unit 2 3 LED Unit 4 Body 5 Dire...

Страница 18: ...with Flange M3 Hexagon Nut with Flange M4 1 pc Pole Waterproof Ring Hexagon Bolt M4 x 20 Hexagon Bolt M3 x 20 No Name 1 2 Head Cover 3 4 Body Mounting Bracket with knock outs Waterproof Packing Silico...

Страница 19: ...11 For M8 screw and nut size For M10 screw and nut size The following requirements are necessary for proper installation Install the signal tower where excessive vibration is not present Install the...

Страница 20: ...el punch etc 4 Insert the hexagon bolt into the knockout holes and affix with the flanged nuts 5 Insert the waterproof packing Select between Direct or Pole mounting KT Direct Mount Pole Installation...

Страница 21: ...ole 6 4 places Mounting Dimensional Drawing WJ WT KT PJ Mounting Hole 3 places 0 6 N m Recommended Torque 1 4 N m Recommended Torque Unit mm 4 5 30 40 LR4 5 WJ LR5 WT KT LR4 5 6 PJ LR6 7 WJ LR7 WT KT...

Страница 22: ...mmended Torque Unit mm Mounting Hole 31 Nut M30 WC While holding part A install the 1 2 NPT Failure to comply may result in damage 2 25 N m Recommended Torque Installation Figure 1 2 NPT Installation...

Страница 23: ...to comply will result in product damage Do not control the flashing display by switching the power source ON and OFF for Product failure will occur It is not necessary to connect to an external lead f...

Страница 24: ...C Class 2 Fuse 1A PLC Transistor Schematic E C B PLC PNP Transistor External Contact Classification LR4 LR7 Used when buzzer unit is attached LED Red LED Amber LED Green LED Blue LED White Power Suppl...

Страница 25: ...ly Wire Red Orange Green Blue White Yellow Flashing Common Line Brown Buzzer Power Supply Wire Purple Gray PLC NPN Transistor External Contact Classification 24 V DC Class 2 Fuse 1A 24 V DC Class 2 Fu...

Страница 26: ...hite Power Supply Wire Flashing Common Line Buzzer Power Supply Wire Red Orange Green Blue White Yellow Brown Purple Gray Lighting LR5 12 V DC only Class 2 24 V DC Class 2 Fuse 1A PLC Transistor Schem...

Страница 27: ...t used Not used Not used Not used Not used LED Red LED Amber LED Green LED Blue LED White Power Supply Wire Red Orange Green Blue White Yellow Flashing Common Line Brown Buzzer Power Supply Wire Purpl...

Страница 28: ...ting Buzzer PLC LR4 LR6 Fuse 1A 100 240 VAC PLC NPN Transistor External Contact Classification LED Red LED Amber LED Green LED Blue LED White Power Supply Wire Red Orange Green Blue White Yellow Flash...

Страница 29: ...n Blue White Yellow Flashing Common Line Brown Buzzer Power Supply Wire Purple Gray Lighting Common Line Black E C B Schematic Output Unit B Output Unit A Flashing Buzzer Lighting Buzzer Used when buz...

Страница 30: ...LED Blue LED White Power Supply Wire Buzzer Power Supply Wire Lighting Buzzer Used when buzzer unit is attached 24 V DC Class 2 Fuse 1A PLC Transistor Schematic E C B PLC PNP Transistor External Conta...

Страница 31: ...Supply Wire PLC NPN Transistor External Contact Classification 24 V DC Class 2 Fuse 1A 24 V DC Class 2 Fuse 1A E C B Transistor Schematic Output Unit Lighting PLC PNP Transistor External Contact Clas...

Страница 32: ...minal Block When removing the lead wire do not pull to remove be sure to operate the lever to release the lock Remove the connector from the body unit before wiring Attach the terminal block connector...

Страница 33: ...ower is disconnected before changing fuses Recommended Fuse External Contact Capacity Fuse Rated Current 250V 1A 5x20mm Fast Acting Glass Body Cartridge Fuse Inrush Current LED Unit 1 Tier Buzzer Rate...

Страница 34: ...ft side of the Pole releases the bracket to be lowered Depressing the lock allows the Pole to swivel freely 1 For example when moving 90 degrees to the right from an upright position 2 The Pole is pus...

Страница 35: ...body and LED unit Failure to comply may damage the unit Be sure to lock each unit securely when attaching Failure to comply may damage the unit Detach the unit in the following manner Any other metho...

Страница 36: ...unit counterclockwise until it unlocks then pull it upwards to remove LED Unit to Body Attachment Align the Positioning Mark after insertion then turn the unit clockwise to lock it Align the Positioni...

Страница 37: ...counterclockwise until it unlocks then pull it upwards to remove to remove it LED Unit to LED Unit Attachment Align the Positioning Mark after insertion then turn the unit clockwise to lock it Align...

Страница 38: ...buzzer unit counterclockwise until it unlocks then pull it upwards to remove it Buzzer Unit to LED Unit Attachment Align the Positioning Mark after insertion then turn the unit clockwise to lock it Al...

Страница 39: ...ted in the groove If the Buzzer Unit cannot attach properly check that the tab of parts inside the Buzzer Unit are fitted inside the groove If the tab is outside of the groove as shown below refer to...

Страница 40: ...ounterclockwise until the tab fits in the groove Attach the Buzzer Unit to the product If the Buzzer Unit can t be attached try the procedure below Turn this part counterclockwise ghv Vertriebs GmbH A...

Страница 41: ...rds to remove Head Cover to LED Unit Attachment Align the Positioning Mark after insertion then turn the unit clockwise to lock it Locked Unlocked Positioning Mark Unlocked Positioning Mark Locked Ali...

Страница 42: ...ved 1 While holding the LED unit turn the LED unit counterclockwise until it unlocks then pull it upwards to remove 2 Align the Positioning Mark after insertion then turn the unit which is removed 1 c...

Страница 43: ...ched 1 Align the Positioning Mark after insertion then turn the unit clockwise to lock it 2 3 Align the Positioning Mark after insertion then turn the unit which is removed 1 clockwise to lock it ghv...

Страница 44: ...counterclockwise until it unlocks then pull it upwards to remove 2 4 Remove the LED unit located above the unit which is intended to be relocated 3 Align the Positioning Mark after insertion then turn...

Страница 45: ...rn the unit which is removed 2 clockwise to lock it Align the Positioning Mark after insertion then turn the unit which is removed 1 clockwise to lock it ghv Vertriebs GmbH Am Schammacher Feld 47 8556...

Страница 46: ...Unit Topside View Attached LED Unit When the LED Unit will not attach The structure of LED Unit is shown in the below figure Situation Structure When LED Unit is attached the lens tab is usually locat...

Страница 47: ...nding on how it is removed If the product is installed again in this condition it may become damaged Do not remove it as the improper procedure depicts it below A condition occurs in which the lens ta...

Страница 48: ...placed in the groove Turn the internal lens of the LED Unit counterlockwise until the tab fits in the groove Attach the LED Unit to the product If the LED Unit can t be attached try the procedure belo...

Страница 49: ...remove Attachment Align the Positioning Mark after insertion then turn the unit clockwise to lock it Unlocked Positioning Mark Locked Locked Unlocked Positioning Mark Align the Positioning Mark after...

Страница 50: ...signals are applied Is the electric wiring connected correctly A different LED from what I thought lights up when it turns on No Is the Buzzer volume set to minimum Refer to Buzzer Pattern Set up pg...

Страница 51: ...Unit none 500VAC applied for 1min between live part and non current carrying metallic part without breaking insulation No 1 LR7 LR4 QJ PJ LJ WJ QJ PJ LJ WJ WJ WT PJ LJ WJ LR5 LR6 LR7 LR4 LR5 LR6 No 2...

Страница 52: ...ss than 90 RH No Condensation Indoor Only Model LR6 02WCNW 500VAC applied for 1min between live part and non current carrying metallic part without breaking insulation UL Recognized Component File No...

Страница 53: ...perating Ambient Humidity Storage Ambient Temperature Storage Ambient Humidity Mounting Location Protection Rating Withstand Voltage Flashing Rate Model Power Supply Wire Signal Wire Standby Power Con...

Страница 54: ...ettings Refer to Section 6 Buzzer Pattern Set up 60 2 Flashes Per Minute Upright Upright IP65 IEC 60529 NEMA TYPE 4X 13 IP54 IEC 60529 NEMA TYPE 4X 13 More than 1M at 500VDC between live part and non...

Страница 55: ...over 50 W U K Filter Sheet 50 Pole Bracket 50 W U K O ring 60 Head Cover 60 W U Filter Sheet 60 Pole Bracket 60 W U Accessories O ring 40 1 pc Pole Waterproof Ring 1 pc Binding Head Tapping Screw 2 pc...

Страница 56: ...s Pole Waterproof Ring Replacement Parts for LR4 LR5 LR6 LR7 NPT Pole Bracket Assy 60 W Replacement Parts for WC Pole Bracket 70 W U K Accessories O ring 70 1 pc Pole Waterproof Ring 1 pc Binding Head...

Страница 57: ...ature Operating Ambient Humidity LR7 LR6 LR5 LR4 0 065kg 0 060kg 0 040kg 0 035kg Model LR E E 20 50 Less than 90 RH No Condensation Due to the characteristics of the LED elements a variation in differ...

Страница 58: ...the total circumference of the buzzer Unit at 1m Sound Pressure Level Remarks When LR5 01 12V DC type is attached Environmental Condition Buzzer Sound Typical Frequency No 1 No 2 No 3 No 4 Rapid Inter...

Страница 59: ...door Only IP65 with product attached PC 0 04kg Note It s possible to run a cable out from the side 1 Required pole is not included with Outer Dimensions Mounting Dimensional Drawing PJ LR4 PJ LR5 POLE...

Страница 60: ...acket 4 Put the Waterproof Packing on the bottom of Circular Bracket Take a cable out from a side Processing Method This part has perforations to make it possible to run a cable out from the side 1 Re...

Страница 61: ...Dimensions Mounting Dimensional Drawing No Accessories There are no contents of controlled substances exceeding the threshold for the RoHS Directive Unit mm PJ LR4 PJ LR5 QJ PJ LR6 QJ Compatible Mode...

Страница 62: ...direction of insertion 3 Tighten the Binding Head Tapping Screws 2 pcs from underneath the Circular Bracket This part has perforations to make it possible to run a cable out from the side Refer to the...

Страница 63: ...Rating Mounting Location Model Material SZP 003 W U K Remarks Mass Tolerance 10 Indoor Only IP65 with product attached PC 0 03kg Outer Dimensions Mounting Dimensional Drawing No Accessories There are...

Страница 64: ...outside 2 Insert Pole into the Circular Bracket See the figure on the left for details on the direction of insertion 3 Tighten the Binding Head Tapping Screws 2 pcs from underneath the Circular Bracke...

Страница 65: ...pright Mounting Location Indoor Only AL 0 05kg Outer Dimensions WJ WT KT LR4 WJ LR5 Compatible Models No Accessories There are no contents of controlled substances exceeding the threshold for the RoHS...

Страница 66: ...Material SZP 091U Remarks Mass Tolerance 10 Upright Mounting Location Indoor Only AL 0 09kg There are no contents of controlled substances exceeding the threshold for the RoHS Directive Unit mm 1 Dire...

Страница 67: ...the product into the NPT Bracket See the figure on the left for details on the direction of insertion 2 Secure the product from underneath the NPT Bracket Used the screw tapped spacer 3pcs for SZP 090...

Страница 68: ...22 0500AT POLE22 0800AT POLE22 1000AT Compatible Models LJ LR4 LJ LR5 LJ LR6 Compatible Pole Specifications Protection Rating Mounting Location Model Material SZP 917U Remarks Mass Tolerance 10 Indoor...

Страница 69: ...Screws 2 pcs on the pole compatible adaptor 3 Run the wiring through the mounting hole While holding part A secure the Pole compatible Adaptor with included Plain Washer and Hexagon Nut Recommended T...

Страница 70: ...20 Opposite Side 27 SZL 001 L bracket Installation Figure Outer Dimensions Unit mm Mounting Location Model SZL 001 Remarks Mass Tolerance 10 Indoor Only 0 09kg Material SPHC P Specifications There are...

Страница 71: ...ions Protection Rating Mounting Location Model Material SZQ 001W Remarks Mass Tolerance 10 Indoor Only IP65 with product attached PC 0 09kg Outer Dimensions Mounting Dimensional Drawing No Accessories...

Страница 72: ...sert Pole into the Folding Bracket See the figure on the left for details on the direction of insertion 3 Tighten the Binding Head Tapping Screws 2 pcs from underneath the Folding Bracket Installation...

Страница 73: ...Dimensional Drawing Outer Dimensions No Accessories There are no contents of controlled substances exceeding the threshold for the RoHS Directive Unit mm PJ LR4 PJ LR5 QJ PJ LR6 QJ Compatible Models...

Страница 74: ...n the direction of insertion 2 Secure the Pole with the Hexagon Socket Set Screws 2 pcs on the Wallmount Bracket Installation using materials other than the specified accessories is not covered under...

Страница 75: ...ZK 002 W U K Remarks Mass Tolerance 10 Indoor Only PC 0 06kg Protection Rating IP65 with product attached Specifications Outer Dimensions Mounting Dimensional Drawing WT There are no contents of contr...

Страница 76: ...SZK 003 W U K Remarks Mass Tolerance 10 Indoor Only PC 0 07kg Protection Rating IP65 with product attached Outer Dimensions Mounting Dimensional Drawing There are no contents of controlled substances...

Страница 77: ...cation Model SZK 004W Remarks Mass Tolerance 10 Indoor Only PC 0 07kg Protection Rating IP65 with product attached Outer Dimensions Mounting Dimensional Drawing There are no contents of controlled sub...

Страница 78: ...l the cable gland into the Wallmount Bracket from the bottom side Required cable gland is not included Cable gland Installation ghv Vertriebs GmbH Am Schammacher Feld 47 85567 Grafing Telefon 49 80 92...

Страница 79: ...screws of the product into the Wallmount Bracket See the figure on the left for details on the direction of insertion 2 Secure the product with the flanged nuts 3 pcs from underneath the Bracket Prod...

Страница 80: ...places Wire Distribution Hole 12 Recommended Torque 20 SZW 001W Circular Bracket WJ LR4 WJ LR5 WJ LR6 WT KT Compatible Models Specifications Material Mounting Location Model SZW 001W Remarks Mass Tole...

Страница 81: ...n of insertion 2 Secure the product with the flanged nuts 3 pcs from underneath the Bracket Installation using materials other than the specified accessories is not covered under warranty Notice 0 6 N...

Страница 82: ...Accessories Hexagon Nut with Flange 3 pcs Model Number Configuration 940 U SZW U Silver Model Body Color Compatible Direct Mount Bracket Compatible Models Specifications Protection Rating Mounting Loc...

Страница 83: ...B WJ WT LR5 W LE AW LES LU5 SZW 950U Compatible Direct Mount Bracket Accessories Hexagon Nut with Flange 3 pcs Model Number Configuration 950 U SZW U Silver Model Body Color Compatible Direct Mount Br...

Страница 84: ...ration 960 U SZW U Silver Model Body Color Compatible Direct Mount Bracket WJ LR6 W LME Mounting Hole Compatible Model Compatible Models Specifications Protection Rating Mounting Location Model Materi...

Страница 85: ...iguration 970 U SZW U Silver Model Body Color Compatible Direct Mount Bracket Mounting Hole Compatible Model Compatible Models Specifications Protection Rating Mounting Location Model Material SZW 970...

Страница 86: ...d nuts 3 pcs from underneath the Bracket Compatible Direct Mount Bracket Product Attachment SZW 940U SZW 960U SZW 970U Flanged nut 3 pcs Installation using materials other than the specified accessori...

Страница 87: ...until the waterproof packing hits the Compatible Direct Mount Bracket bottom Product Attachment SZW 950U Mounting Hole A Compatible Direct Mount Bracket Compatible Direct Mount Bracket Flanged nut 3 p...

Страница 88: ...Compatible Direct Mount Bracket with M4 screw 2 pcs M4 screw is not included Be sure to prepare mounting screws separately and consider the screw threadto be 14 mm or less in order to attach the Comp...

Страница 89: ...Mounting Location Model POLE22 0100AN POLE22 0100ANK Remarks Mass Tolerance 10 Indoor Only POLE22 0300AN POLE22 0300ANK POLE22 0500AN 100 300 500 0 05kg 0 16kg 0 26kg 0 42kg 0 52kg Notice Use a pole w...

Страница 90: ...d substances exceeding the threshold for the RoHS Directive Pole Length L mm Mounting Location Model POLE22 0100AT Remarks Mass Tolerance 10 Indoor Only POLE22 0300AT POLE22 0500AT 100 300 500 0 05kg...

Страница 91: ...2 ribs are on the outside 2 Insert Pole into the Pole Bracket See the figure on the left for details on the direction of insertion 3 Tighten the Binding Head Tapping Screws 2 pcs from the topside of...

Страница 92: ...le Models Specifications Outer Dimensions Manufactured by the OMRON Corp Cable length L mm Mounting Location Model SZ 120 02 Remarks Number of core wires Indoor Only SZ 120 05 SZ 120 10 2000 5000 1000...

Страница 93: ...93 ghv Vertriebs GmbH Am Schammacher Feld 47 85567 Grafing Telefon 49 80 92 81 89 0 info ghv de www ghv de...

Отзывы: