![Patlite LA6 series Скачать руководство пользователя страница 29](http://html1.mh-extra.com/html/patlite/la6-series/la6-series_operation-manual_3974893029.webp)
29
LA6 Signal Tower Complete Operation Manual
The version is expressed in the order from the LED top to bottom, as shown in the figure below.
For a detailed verification of the current version, the “EDITOR for LA series” software application can be used to check from the
PC.
If there is no personal computer, etc., available in its environment, contact your nearest Patlite Sales Representative and tell them
the status of LED tiers displayed to determine the current firmware version.
To exit from the “Version Confirmation” status, pressing the Multiple-function Button for about 3 seconds, or leaving it for 15
seconds untouched, will automatically cause it to return to it’s normal operation.
6.3.2.3. Product Initialization
The flashing speed of the white LED gradually becomes faster while holding the Multiple-function Button down until the White
LED is in its full flashing state. The first flashing lasts about 15 seconds before the flash rate increases, and by continuing to push
the Multiple-function Button, the White LED goes out after 10 seconds and Initialization (product returns to “Signal Tower” mode
and values are back to factory default) is completed.
Initialization
Complete
Continue pushing button until
initialization is complete.
About 15 sec.
About 5 sec.
About 5 sec.
The White LED flashing gradually becomes faster
Initialization is
complete when
the white LED
goes out.
Slow-flashing
White
Fast-flashing
White
Flashing
White
Ver. .
Note
• If the “Multiple-function” Button is released before initialization is completed, it returns to the “Signal Tower” mode.
• After pushing the “Multiple-function” Button, the standard time to completely return to factory default is 30 seconds.
• Initialization is only possible in the “Signal Tower” mode.