LA6 Signal Tower Complete Operation Manual
In addition to trigger input and pattern changes, the figure shows the operation of the “Mute” input and the “Clear” input.
6.2.3. “Single-display” mode
There are 31 group varieties with the product’s internal memory that can be used in combination of ON/OFF inputs from signal
wire inputs 1-5 to operate the LED display colors. Although the Flashing/Alarm functions can be used, the LED wave-like color
flow, etc., cannot be used.
The setup for each group can be made in the “EDITOR for LA series” software application (Visit our homepage at
http://www.
patlite.com/
to download the software application and other features for the LA6.).
• Setup Parameters
This mode has parameters that can be set up as shown in the following table.
Setup Range
Setting Index
Description
Every Group
LED Lighting/Flashing
Select all LEDs to turn on or flash. Flashing rates are selectable from 30
times per minute, 60 times per minute, or 120 times per minute.
Alarm Tone
Alarm Silence or one tone can be selected from 11 varieties.
Every Tier
LED Color
LED lights On or Off can be selected.
Note
The one shot trigger input pulse acquires only the rise-time of the input. Refer to “8.1. Basic Signal Input Time Chart”
on page 38 for more details.
Operating
Condition
LED
OFF
1/-
1/1
1/2
1/3
...
1/60
1/61
1/62
1/1
1/2
OFF
Buzzer
Mute
Mute
Mute
Signal Input
Input 1
Input 2
Input 3
Input 4
Input 5 (STOP)
Input 6 (Mute)
Input 7 (Clear)