38
Signal Tower LA6-POE Operation Manual
5.1.6. Clear Command
Command Description
Turn off the LED unit and stop the buzzer.
Transmission Data Format
Product Category
AB
Identifier
C
Open
Data Size
41H
42H
43H
00H
00H
00H
Product Category
The product is classified in “AB.”
Identifiers
“C” is used.
Data Area
There is no data area.
Reply Data
Normal Response (1 byte)
Abnormal Response (1 byte)
ACK
NAK
06H
15H
5.1.7. Reboot Command
Command Description
This product can be rebooted.
Transmission Data Format
Product Category
AB
Identifier
B
Open
Data Size
Data Area 1-16 bytes
41H
42H
42H
00H
00H
01H-10H
See Below
Product Category
The product is classified in “AB.”
Identifiers
“B” is used.
Data Size
Enter the number of bytes for the data area.
When the value is “patlite”.
00H
07H
Data Area
Enter the password which is set up in the password setting of the Web Setup as an ASCII code.
Reply Data
Normal Response (1 byte)
Abnormal Response (1 byte)
ACK
NAK
06H
15H
Command Response Example
When the password is set to “patlite”.
Product Category
AB
Identifier
B
Open
Data Size
Data Area
p
a
t
l
i
t
e
41H
42H
42H
00H
00H
07H
70H
61H
74H
6CH
69H
74H
65H