Signal Tower LA6-POE Operation Manual
5.1.1. Smart Mode Control Command
Command Description
The Smart Mode can be executed with the number specified in the data area.
Transmission Data Format
Product Category
AB
Identifier
T
Open
Data Size
Data Area
1 byte
41H
42H
54H
00H
00H
01H
See Below
Product Category
The product is classified in “AB.”
Identifiers
“T” is used.
Data Area
Data area byte: 1Byte
01H (Group No. 1)-
1FH (Group No. 31)
Reply Data
Normal Response (1 byte)
Abnormal Response (1 byte)
ACK
NAK
06H
15H
Command Transmission Example
Smart Mode group 10 is executed.
Product Category
AB
Identifier
T
Open
Data Size
Data Area
1 byte
41H
42H
54H
00H
00H
01H
0AH
MEMO
• When executing single display type, or group No., up to 31 (01H-1FH) can be designated.
• To execute the time trigger type or pulse trigger type, up to 15 (01H - 0FH) groups can be specified
when setting up.