background image

 

ASSEMBLY INSTRUCTIONS Model PH-45-FS-LP & Model PH-50-FS-N 
Free standing model for use will approved flexible supply line. 
 

S

tep 1 

Determine a safe, level and suitable location for 
the weighted base. 
 
Step 2

 

Remove the 3/8” x 1” bolt in the base of the 
heater head and set aside. (Figure 2 previous 
page 7). Secure heater head to flexible hose 
protruding from the top of the post.  Use two 
pipe wrenches to securely tighten.  A suitably 
approved gas pipe sealant must be used for all 
gas connections.  Slide head assembly into post. 
Align the 3/8” hole in the post with the 3/8” 
threaded hole in the base of the heater head, and 
replace the 3/8” x 1” bolt.  Secure tightly. 
 
Step 3 
Slide the decorative cover onto the post from the 
bottom.  Place the post into the basemount “T” 
on the weighted base and slide the decorative 
cover down over the post retainer.  Connect gas 
supply to nipple protruding from the lower end 
of the tube.  A suitably approved flexible gas 
line must be used for connection to the gas 
supply.  Flex gas line is not included.  Consult 
the local authorities for information on the types 
of flexible lines and quick connection couplers 
that are available in your area. 
 
Step 4 
Secure the reflector to the heater head with the 

hardware provided.  Gas supply and electrical 
supply are to be according to all local and 
applicable codes.  Only those individuals 
licensed and qualified in the installation of gas 
fired heating appliances are to install this 
appliance. 

Gas  shutoff
by others

Dec orative
Cover

Weighted
base

Basemount “T”
top view

Содержание PH series

Страница 1: ...tentivement les instructions d installation de fonctionnement et d entretien avant de proc der l installation ou l entretien de cet quipement This manual applies to the following Patio Plus models PH...

Страница 2: ...ustment alteration service or maintenance can cause injury property damage or death Read the complete installation manual and all warning labels on the appliance before installation or servicing this...

Страница 3: ...maintained Combustible materials are considered to be wood compressed paper plant fibers or other materials capable of being ignited and burned Such materials shall be considered combustible even thou...

Страница 4: ...atios must be large enough to meet the clearance to combustibles and ventilation requirements as provided for in all applicable codes For very small enclosed patios Patio Plus heaters may not be suita...

Страница 5: ...tach regulator to your L P tank or gas line securely Leave the L P tank outside the cabinet for the testing procedure 3 Open the valve of the L P tank or turn main gas valve to heater ON then leave th...

Страница 6: ...be used on L P gas special precautions should be observed when handling L P cylinders Remember that this is gas and under pressure which must be handled with care Ask your L P gas dealer to show you t...

Страница 7: ...ulator assembly Always store L P cylinders in a well ventilated space If you intend to store the heater indoors disconnect the L P cylinder and store it outside Disconnected cylinders must have a thre...

Страница 8: ...the 3 post The top of the post can be identified by the 3 8 hole being at the top end Line up the 3 8 hole in the post with the 3 8 hole in the base of the heater head and replace the previously remo...

Страница 9: ...de the decorative cover onto the post from the bottom Place the post into the basemount T on the weighted base and slide the decorative cover down over the post retainer Connect gas supply to nipple p...

Страница 10: ...y into post Align the 3 8 hole in the post with the 3 8 threaded hole in the base of the heater head and replace the 3 8 x 1 bolt Secure tightly Step 4 Slide the decorative cover onto the post from th...

Страница 11: ...f the heater head and replace the 3 8 x 1 bolt Secure tightly Step 4 Insert post into the ground support pipe and fasten with hardware provided Connect the gas supply to the nipple protruding from the...

Страница 12: ...sition Ensure that the heater is installed so that it hangs level to the ground and that stress cannot be created on the gas supply piping Step 3 Apply a suitably approved pipe sealant to the nipple p...

Страница 13: ...b will be in an immovable position Wait 90 seconds and the thermocouple will cool and knob will be released to re light pilot To Light Main Burner except Direct Lite After pilot is lit wait 30 seconds...

Страница 14: ...e has no pilot Defective thermopile Defective gas valve Dirty pilot Replace thermopile Replace gas valve Clean pilot Main Burner won t light No 24 Volt power to unit Low gas pressure Blockage in orifi...

Страница 15: ...ds a 3 YEAR warranty from the date of purchase to the original purchaser of this product against manufacturing defects in material and workmanship If this product fails to operate because of a manufac...

Страница 16: ...16...

Страница 17: ...17...

Страница 18: ...18...

Страница 19: ...19...

Страница 20: ...20...

Отзывы: