October 2021
45
PWPP HH P1 - Manual
FACTORY DEFAULT
In the event of a loss of communication with the device, it is possible to reset it to factory settings.
To factory default the PWPP HH P1, press any button twice to enter the main menu, which will show
Gateway Config
as the
first menu item. Press the
OK
button to enter the menu.
PWPP HH P1
Univ1 LiveOut
→
Gateway Config
NEXT OK ESC
The first menu item in the
Gateway Config
menu is the
Factory Default
item. Press the
OK
button.
Factory Default
NEXT OK ESC
→
Gateway Config
SECURE ESC
The next screen will show the current value for the property. You will need to change the value to “
Enabled
” to complete the
Factory Default process. Press the
EDIT
button, and then press the
UP
or
DOWN
button to change the value to
Enabled
,
then press the
NEXT
button.
Disabled
EDIT ESC
→
Enabled
UP DOWN NEXT
Finally, on the next screen you must press the
SAVE
button to confirm. The device will then perform a factory default and will
reboot itself. To cancel without performing a factory default, press the
ESC
button to cancel and return to the previous menu.
Enabled
SAVE ESC
→
Booting...
→
10.2.223.35
Univ1 IdleOut
The device will then reboot, having reset itself to Factory settings. Note the device’s IP address will be reset to the default
(starting with 10.x).
Before configuration can be restored, the unit’s Security Mode must be configured (add to a Security Domain, or enable Local
Configuration Mode).
Содержание Pathport PWPP HH P1 XLR5F
Страница 7: ......