MODEL 7150 16-CHANNEL RJ45 RS-232 A/B SWITCH WITH AUTOMATIC FALLBACK, GUI, AND
CASCADE
Electro Standards Laboratories, Inc.
(401) 943-1164
www.electrostandards.com - pg 37 - Pub. 6026-02
o
If 2 Cascade In ports or 2 Cascade Out ports are
connected, the units and cascade will still function,
but not optimally.
When attempting to make a position change for a channel, other
channels switch with it.
•
This is the normal operation of multiple channels if they are in
the same group. This is also the normal operation of multiple
channels in the same group across a chain. To check to see
what channels are in a group, look at the Graphical User
Interface using the remote.
Channels in the same group are in different position or lockout
states.
•
If for any reason the units in the same group are in different
position, lockout state, or mode of operation, the user should
toggle the position back and forth once to sync the existing
group.
•
This error will only happen if plugging in units to a cascade
chain where channels are in the same group but different
positions. It is recommended to plug in units to a cascade chain
by removing the channels from groups prior to plugging in
cascade chains. After this, the user can configure groups
through the remote Graphical User Interface.
Remote Connection Issues
Figure 21 Lost Connection to Unit