DS 350 G Boom Control Troubleshooting- TMS/TTS870 / RT865 BXL
031-300-190-039 Rev. B 4/30/99
62
18.1 Additional Error Codes - Operational
Error code
Description
Solution
E18
Front Stabilizer overloaded
Achieve a safe working area immediately.
E83
The outer mid section and fly section
are not fully retracted while the center
mid section or the inner mid section
retracts or extends.
No cut off with E83, but
flashing pre-
warning light
in console and
reduced
capacity chart
(rigging mode).
Select manual mode.
Manually retract the outer mid and fly section
until fully retracted. Return to auto mode.
Check fly section cable adjustment. The fly
section shall not be extended when center
mid section is fully retracted.
Flashing %
indication
Out of telescope sequence (rigging
mode selected). The red warning light
“Out of sequence” in the console
panel lights up.
Select manual mode.
Rectify the solution by manually operating
each telescope until % indication stops
flashing and the red warning light “Out of
sequence” in the console panel is dim.
Return to auto mode.