DS 350 G Boom Control Troubleshooting- TMS/TTS870 / RT865 BXL
031-300-190-039 Rev. B 4/30/99
3
5. Boom Control Interface
LMI Circuit
Boom
control
circuit
Digital
Input
Relays
output
Analog input
Analog output
Crane interface
connector
Crane interface
connector
P-switch extend pilot pressure
P-switch retract pilot pressure
Automode switch in cabin
Front O/R pressure switch
Prox.switch on base section
Prox.switch on IM section
Boom retract
Boom extend
Auto mode on
House lock engaged
Inner mid retracted
Center mid retracted & 0%
IM 2- way valve
Rod side dump
valve
Tele out of
sequence
Proportional
output / extend
Prop.
K2
K3
K4
K5
K6
K5
Proportional
output / retract
2- way valves (inner mid)
Rod side dump valve
Out of sequence warning light
pressure reducing valve/
retract
pressure reducing valve/
extend
Center mid length sensor
Main boom length sensor
Main boom angle sensor
Rod pressure transducer
Piston pressure transducer
LMI Console
870 - LMI (751)
DI 1
DI 2
DI 3
DI 7
DI 6
DI 11
Inner mid length sensor
CM 2- way valve
OM 2- way valve
K7
2- way valves (center mid)
2- way valves (outer mid)
K5
DI 8
DI 9
Auto mode A *
Front O/R overloaded
DI 4
OM/Fly retracted & 0%
Inner mid 0%
DI 5
Area def. switch *
Prox.switch on base section
Prox.switch on CM section
House lock switch (EEC units) *
Automode A selector switch
* = RT 865BXL only
Drawing 1.
PAT Equipment Corporation reserves proprietary rights to this drawing and to the data shown there on. The drawing and data are
confidential and are not to be used or reproduced without the written consent of PAT Equipment Corporation. This drawing is subject to
technical modification without prior notice.