DS 350 G Boom Control Troubleshooting- TMS/TTS870 / RT865 BXL
031-300-190-039 Rev. B 4/30/99
48
14. Continuation
Continuation
Is the
voltage correct?
[O turns = - 500mV
10 turns= - 4.5V]
Refer to page18 and reset length
transducer. Possible main board defect.
Contact authorized service dealer for
further assistance.
Yes
No
Defective length potentiometer
assembly. Replace and adjust length
potentiometer. Refer to drawing on