Error Code
Error
E01
Fallen below the radius or above angle range
E02
Radius range exceeded or fallen below angle range
E03
Boom position is out of the permissible working area
E04
Operating mode not existing
E05
Prohibited length range
8
TROUBLESHOOTING
General
In case of a malfunction of the system, the display (1) will indicate a code that identifies the
system malfunction.
The error codes listed in the Malfunction Table will identify various faults that can occur with
the RCL. Following the Malfunction Table are pages, which explain each fault and describe the
action, which shall be taken to correct the fault.
Faults within the electronic microprocessor shall be repaired by factory trained service personnel.
When these faults occur, the competent service organization shall be contacted.
Malfunction Table
NOTE:
If there is any Error Code displayed on the console, which is not listed in the
Malfunctions Table, you shall call the Local Distributor.