background image

 

November 18, 2010                                    Rev 1.02 

15

 
 

Pass Warranty 

Rev 1 of 
August 11, 2008 
 
 
 
 
Please check with the factory authorized distributor in the country 
where you are purchasing this product for specific warranty 
information. 
 
All Pass Laboratories products purchased new from an authorized 
Pass Laboratories dealer in North America are covered by a 
transferable, limited 3-year warranty. This warranty includes all parts 
and labor charges incurred at the factory or factory specified repair 
facility, exclusive of any subsequent or consequential damages. 
Damage due to physical abuse is specifically excluded under this 
warranty. 
 
For this warranty to apply the customer is responsible for returning the 
product unmodified to the factory within the specified warranty period.  
The customer assumes all responsibility for shipping and insurance to 
and from the factory or a factory specified repair facility. The conditions 
and stipulations of this Pass Laboratories warranty only applies to units 
originally sold new through an authorized dealer.  Warranty on factory 
repair is 60 days and covers only the scope of the original repair. 
 
Non-North America customers should consult with their original Pass 
Labs dealer or distributor for warranty repair instruction prior to 
contacting the factory or shipping product to the factory for repair.  
 
Non-North American product must be returned to the country of origin 
for warranty service.  Foreign distributors are only required to offer 
warranty service on Pass Laboratories product that they have 
imported, verifiable by serial number. 
 
Please note: Conditions of warranty service and customer rights for 
product purchased outside the United States may vary depending 
upon the distributor and local laws. Please check with your local 
distributor for specific rights and details. 
 
 
 
 

Содержание XP-10

Страница 1: ...November 18 2010 Rev 1 02 1 PASS XP 10 Owner s Manual ...

Страница 2: ...te an after market product we urge you to choose one that is fully safety rated by the necessary local authority Power Cord Protection Power supply cords should be routed so that they are not likely to be walked on abraded or pinched by items placed on or against them paying particular attention to cords where they enter plugs or exit from a device Never under any circumstance insert a cut or dama...

Страница 3: ...presented by models X0 2 X1 and X2 5 The X series pre amplifiers have received many highly respected and well deserved accolades over the past 11 years justifiably so More importantly they have provided a solid foundation from which the current and newest product has evolved These new pre amp offerings from Pass Laboratories objectively sound and measure significantly better than their immediate p...

Страница 4: ...experience the XP series product Collectively audiophiles tend to listen quite a bit differently today than they did when the original X preamps were created and the XP line of product have all been designed to reflect those changes in listening style Pass Laboratories has redesigned the remote control to allow direct access to the most frequently wanted control functions thus simplifying and enha...

Страница 5: ...w pre amplifier hundreds of hours of thoughtful listening and careful adjusting have produced a product where the enhanced detail simply comes through as greater spatial refinement and dynamic accuracy without any loss of musicality Bass definition is better than in pervious models highly dynamic passages typically have more weight a more accurate leading edge with increased control and the spectr...

Страница 6: ...lowly stabalize over the first 24 hours of operation and thereafter will be at their sonic best Be aware however that if you unplug or otherwise remove power from the unit that the warm up period starts afresh Please give this product at least 24 hours initial warm up time before attempting any critical listening Like virtually all modern digital product there is no off in the traditional sense Th...

Страница 7: ...ndicate 240 volts 220 volts 120 volts or 100 volts A 1 0 amp 3AG slow blow fuse is provided with 100 120 volt units and a 0 5 amp slow blow fuse is provided with 220 240 volt units The input frequency rating of the power supply is 50 to 60 Hz The preamplifier typically draws 10 watts during operation Please verify that the indicated voltage requirement of this preamplifier is consistent with the u...

Страница 8: ... with L for left and R for right channel The main outputs are located at the left hand side viewed from the rear of the rear panel two male XLR connectors and two RCA connectors R right and L left The RCA connector s ground is in parallel with pin 1 of the XLR outputs and the RCA hot is fed from an independent summing junction that maximizes the X circuit benefits The RCA single ended outputs are ...

Страница 9: ... right pointing arrows then alter the displayed active input 1 through 5 Input 5 is unique in that it is linked with the Home Theater Unity Gain function The HOME THEATRE FUNCTION is discussed at length later in this manual The two select arrows logically control selections of the various inputs to the preamplifier The theater pass through function bears special attention this function is only ava...

Страница 10: ...ow gain and setting the volume at step 75 Before selecting the theatre pass through pass thru option it is imperative that the input device on input number 5 has its gain set to some minimum level Failure to follow this precaution could result in a volume level intolerable to both ears and speakers We have designed this product so that the volume setting of the preamplifier will always revert to t...

Страница 11: ...controls Power tape and ext amp on external amplifier turn on have no reality with the XP 10 These specific control functions have no effect on this product MUTE pressing mute once will quiet the pre amplifier outputs pressing mute a second time will return you to the previous volume control setting INPUT SELECTION Pressing 1 2 3 4 5 will immediately move the input selection to that input selectio...

Страница 12: ...e command sequence aborts and the XP 10 resorts to its previous status DISPLAY The default setting for the display is bright pressing the display button once changes the display to its dim or low intensity setting pressing the button a second time selects off for the display When off is selected any other control function will cause the display to indicate product operational status for approximat...

Страница 13: ... a manner that achieves the noise rejection of active balanced sources The use of a micro controller allows all of the preamplifier functions to be repeatable and accurately controlled The micro processor only controls the functions of the preamplifier At no time does any of the input or output signal come into contact with the digital control signals The digital circuits are powered by a power su...

Страница 14: ...B 2 Hz and 60 kHz Input Impedance 96 k ohm balanced 48 k ohm single ended Output Impedance 1000 Ohm balanced 150 ohm single ended CMRR 60 dB 1 kHz Cross talk 90 dB 1kHz Ref 1V Signal to Noise Ratio 110 dB Ref 5V Power Consumption 10 watts Dimensions Chassis 17 W x 12 D x 4 H Shipping Weight 32 pounds in packing carton ...

Страница 15: ...or shipping and insurance to and from the factory or a factory specified repair facility The conditions and stipulations of this Pass Laboratories warranty only applies to units originally sold new through an authorized dealer Warranty on factory repair is 60 days and covers only the scope of the original repair Non North America customers should consult with their original Pass Labs dealer or dis...

Страница 16: ...sues being corrected to the most recent accepted standards Removal or alteration of original Pass Labs serial numbers voids the factory warranty Product with altered or missing serial numbers will be suspect as counterfeit or stolen product Pass Laboratories will not repair or in any way indemnify any counterfeit or cloned product Pass Laboratories does not offer products in voltages intended for ...

Страница 17: ...November 18 2010 Rev 1 02 17 ...

Страница 18: ...Laboratories P O Box 219 Foresthill CA 95631 Voice 530 367 3690 Fax 530 367 2193 www passlabs com Pass PASS Pass Labs Pass Laboratories Supersymmetery Aleph and Zen are all registered trademarks of Pass Laboratories Inc and law thereto protects all rights ...

Отзывы: