4. Remove seal plate.
5. Place seal plate face down on flat
surface and tap out stationary half
of seal (See Figure 7).
INSTALLING NEW SEAL
1. Clean seal cavity in seal plate;
clean shaft.
2. Wet outer edge of Rubber Cup on
ceramic seat with liquid soap. Be
sparing!
3. Put clean cardboard washer on seal
face. With thumb pressure, press
ceramic half of seal firmly and
squarely into seal cavity (See
Figure 8). Polished face of ceramic
seat is up. If seal will not seat cor-
rectly, remove, placing seal face up
on bench. Reclean cavity. Seal
should now seat correctly.
4. If seal does not seat correctly after
recleaning cavity, place a cardboard
washer over polished seal face and
carefully press into place using a
piece of standard 3/4” pipe as a
press.
IMPORTANT:
Be sure you do not
scratch seal face.
5. Dispose of cardboard washer and
recheck seal face to be sure it is
free of dirt, foreign particles,
scratches, and grease.
6. Inspect shaft to be sure it is free of
nicks and scratches.
7. Reassemble seal plate to motor
flange.
8. Apply liquid soap sparingly (one
drop is sufficient) to inside diameter
of rotating seal member.
9. Slide rotating seal member (carbon
face first) onto shaft until rubber
drive ring hits shaft shoulder (See
Figure 9).
IMPORTANT:
Be sure not to nick or
scratch carbon face of seal when pass-
ing it over threaded shaft end or shaft
shoulder. The carbon surface must
remain clean or short seal life will result.
10.Hold motor shaft with 7/16” open end
wrench on shaft flats and screw
impeller onto shaft. Be sure you do
not touch capacitor terminals with
body or any metal object. Tightening
impeller will automatically locate
seal in correct position.
11. Remount diffuser on seal plate.
12. Install new diffuser gasket (Key No.
8A or 8B). BE SURE to match the
new gasket with the old gasket you
removed during disassembly.
13. Follow instructions under “Pump
Reassembly”.
PUMP REASSEMBLY
1. Install new gasket; mount motor on
pump body and install four cap-
screws.
2. Replace pressure switch tubing and
motor wiring; close drain cock.
3. Prime pump according to instruc-
tions under “Operation” in your
owner’s manual.
4. Check for leaks.
REMOVING OLD SEAL (continued)
2
Figure 7
506 0194
Figure 8
Ceramic
Face
Car
b
on
Face
Be Caref
u
l
That Motor
Shaft Sho
u
lder...
...Does
N
ot
Damage Seal Face
Figure 9
8
A
8
B
Figure 10
Pump Brand
For Use With Kit No.:
FPP1560
FPP1561
Flotec
FP4101, FP4112, FP4212
FP4122, FP4222
Southern States
LCSSI-02, NCSSI-02
LDSSI-02
Moore-Handley
ABFLC30H, ABFLC-01L
ABFLD-01L
Teel
4RJ47
4RJ48, 4RJ49
Mastercraft
312222 Series
313521, 312222 Series
Seal and Gasket Kit FPP1550 works with all models listed above.